13
MAINTENANCE
Daily maintenance
Cleaning of air filter
1
Push the
button to stop the operation,
then turn off the circuit breaker.
After the cooling or dry operation, the
ventilation fan keeps running for
self-cleaning. Push the
stop the operation.
Take out the air filter
1
Open the air intake grille until it stops, and
slightly raise the hook on the lower centre
of the air filter.
The air intake grille should not be opened
further; otherwise, the arms may come off and
the air intake grille may fall down.
Cleaning with water or vacuum cleaner
• If dirt is heavy, clean the air filter by tepid water
with neutral detergent or water.
• After cleaning with water, dry the air filter
sufficiently in a shade place.
Mount the air filter
2
button twice to
1,2
‒ 44 ‒
Turn on the circuit breaker, then push the
button on the remote controller to start
the operation.
CAUTION
• Do not start the air conditioner while leaving
air filter removed.
Installation Manual
44-EN