Panasonic CS-E9EKK Service Manual page 25

Hide thumbs Also See for CS-E9EKK:
Table of Contents

Advertisement

10.1.2.2. Horizontal Airflow
1. Automatic horizontal airflow direction can be set using remote control; the vane swings left and right within the angles as
stated below. For heating mode operation, the angle of the vane depends on the indoor heat exchanger temperature as Fig-
ure 1 below.
Heating, with heat exchanger temperature
Cooling, Soft Dry
2. Manual horizontal airflow direction can be set using remote control; the angles of the vane are as stated below and the
positions of the vane are as Figure 2 above.
Pattern
Airflow Direction
Patterns at Remote
Control
Vane Angle ( ° )
10.1.3. Quiet operation (Cooling Mode/Cooling area of Soft Dry Mode)
A. Purpose
To provide quiet cooling operation compare to normal operation.
B. Control condition
a. Quiet operation start condition
• When "quiet" button at remote control is pressed.
Quiet LED illuminates.
b. Quiet operation stop condition
1. When one of the following conditions is satisfied, quiet operation stops:
a. Powerful button is pressed.
b. Stop by OFF/ON switch.
c. Timer "off" activates.
d. Quiet button is pressed again.
2. When quiet operation is stopped, operation is shifted to normal operation with previous setting.
3. When fan speed is changed, quiet operation is shifted to quiet operation of the new fan speed.
Operation Mode
1
2
90
65
Vane Angle ( ° )
A
65 ~ 115
B
65 ~ 115
3
78
25
90
4
5
102
115

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cs-e12ekkCu-e9ekkCu-e12ekk

Table of Contents