To the right of the power supply bays, the processor slots house the processor modules. In the Cisco
7000, the RP is always located in the far right slot (the RP slot), and the SP (or SSP) is always located
in the adjacent slot. The remaining five interface processor slots, numbered 0–4 from left to right,
support any combination of network interface types: serial, FDDI, Ethernet, and Token Ring, and so
forth.
In the Cisco 7507, the RSP2 is always located in slot 2 or 3. The remaining six interface processor
slots, numbered 0 and 1 and 4 through 6, from left to right, support any combination of network
interface type.
The processor modules slide into the slots and connect directly to the backplane. The backplane slots
are keyed to guides on each type of board. (See Figure 4 for the Cisco 7000 and Figure 5 for the
Cisco 7507.) The keys ensure that the processor modules can be installed only in their designated
slots.
Figure 4
processors, RP and SP (or SSP)
Interface processor
Interface processor
4 Cisco 7000 and Cisco 7507 Chassis Replacement Instructions
Power Supply Safety Interlocks
Safety interlock
switch
Cisco 7000 System Backplane Slot Key Guides
Key guides on interface
Top
Top
key guide
slots 0–5
SSP (or SSP)
RP
Rear of
processor card
Bottom
slots 0–5
SSP (or SSP)
Bottom
key guide
RP
Locking device
in ON and
locked positions