Kenmore 795.74092.41 Series Service Manual page 86

Table of Contents

Advertisement

11-2 Check B
B1. LED blinks once, then repeats (FCT0 Fault)
Blink
OFF Blink OFF
- Purpose: Detecting motor current and voltage error
- Check voltage at point A (Motor Voltage), point B (Motor Current) and Point C (Capacitor
Voltage) when compressor is off.
- Spec: Points A, B, & C 2.5V
Protection
Blink 1 time
logic
(FCT 0) Check B1
Check B
Out of spec?
(2.2 - 2.8V)
N
Reset Power
B2. LED blinks two times, then repeats (Stroke Trip)
Blink
Blink OFF Blink Blink OFF
- Purpose: Prevent abnormally long piston strokes.
- Case 1. If compressor doesn't work and LED blinks - Cause: Possibly harness from compressor to PCB might be
defective.
- Case 2. If compressor works intermittently and LED blinks - Cause: Condenser Fan or Freezer Fan is not running. Sealed
system problem such as moisture restriction, restriction at capillary tube or refrigerant leak.
- Logic: Compressor is forced to off and then tries to restart after 1 minute.
Protection
Blink 2 times
logic
(Stroke Trip) Check B2
Check B
Compressor
Doesn't work
Replace
Driver PCB
OK
NG
Fix
Cycle
Cycle
Check E
Repeat
Check Procedure
0.3V
Y
Replace Driver PCB
N
Harness
Y
Connecting
Check C
N
Compressor
Works Intermittently
Y
N
Stroke Trip
Occur?
- 86 -
Protection Logic
Protection Logic
Fix Harness
Y
Y
Capacitor
Spec.
Check C
Y
Compressor
Damage
Reset
Check C
Power
Y
N
Replace
Capacitor
N
Replace
Compressor

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

795.74093.41 series795.74099.41 series

Table of Contents