Bosch Climate 5000 Series Installation Instructions Manual page 11

Multi zone ductless air conditioner / heat pump
Hide thumbs Also See for Climate 5000 Series:
Table of Contents

Advertisement

Split type outdoor unit mounting dimensions
Outdoor Model
Dimensions mm (in.)
BMS500-AAS012-0CSXRC
765x555x303 (30.1x
BMS500-AAS009-1CSXRC
BMS500-AAS012-1CSXRC
BMS500-AAS009-1CSXHC
805x554x330 (31.7x
BMS500-AAS012-1CSXHC
BMS500-AAS018-1CSXRC
890x673x342 (35.0x
BMS500-AAS018-1CSXHC
BMS500-AAM018-1CSXRC
BMS500-AAS030-1CSXRC
BMS500-AAS036-1CSXLC
BMS500-AAS036-1CSXRC
BMS500-AAS024-1CSXRC
946x810x410 (37.2x
BMS500-AAS024-1CSXHC
BMS500-AAM027-1CSXRC
BMS500-AAM036-1CSXRC
BMS500-AAM018-1CSXHC
BMS500-AAM027-1CSXHC
BMS500-AAS060-1CSXLB
BMS500-AAS048-1CSXLC
952x1333x415
BMS500-AAM048-1CSXRC
(37.5x 52.5x 16.34)
BMS500-AAM036-1CSXHC
BMS500-AAM048-1CSXHC
Table 6
Split Type Outdoor Unit
D
Figure 7
Bosch Climate 5000 Series Multi Zone Ductless Air Conditioner / Heat Pump (06.2022)
Mounting Dimensions
Outdoor Unit
mm (in.)
W x H x D
Distance A
Distance B
454 (17.8)
286(11.3)
21.8x 11.9)
511 (20.1)
317(12.5)
21.8x 13.0)
663 (26.1) 348 (13.7)
26.5x 13.5)
673 (26.5) 403 (15.9)
31.9x 16.1)
634 (25.0) 404 (15.9)
H
W
W
H
A
B
Series installation
The relations between H, A and L are as follows:
L
L ≤ 1/2H
L ≤ H
1/2H < L ≤ H
L > H
Table 7
H
Figure 8
The minimum distance between the outdoor unit and walls described
in the installation guide does not apply to airtight rooms. Be sure to keep
the unit unobstructed in at least two of the three directions (M, N, P)
(See Fig. 9)
M
N
Figure 9
Installation Instructions
A
9.8in / 25 cm or more
11.8in / 30 cm or more
Can not be installed
P
| 11
L

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents