6.2 General description of user parameter settings
Click on the [Settings] key on the main interface, and
Enter
input the password, the system will show the system
Setting
setting interface.
This function is used for setting user parameters.
User
The default password is 123456.
This function is used to set the engineer parameters.
Engineer
The default password is 999999.
6.3 Description of intercom account settings
Display
Date, time, language, brightness,these can be set on
setting
this interface.
The user can press the [Gain the Time] key to acquire
Others
time from the service software or guard machine.
6.4 Description of display settings
The ring tone, ring back tone, ring tone volume and
Volume
keypad Tone can be set in this interface.
setting
6.5 Description of alarm parameter settings
In security parameter settings, user can set the arm
Settings
delay time, alarm delay time, Alarm Repeat Time(s),
(s), remove setting, absent setting, home settings, etc.
This time generally represents the time from the
moment when the user performs the arming operatio-
Arm
non tomoment when the devices start to monitor
delay
the zone. Generally, the time lasts from the moment
time
of arm setting to the moment when the user steps
out of the house ( The default value is 60 seconds).
This time generally represents the time from the
moment when the zone of the type [Delay] triggers
alarm to the moment when an alarm relay occurs.
Alarm
Usually, this time lasts from the moment when the
delay
user steps into the house (trigger the door magnet
time
and the infrared) to the moment when the devices is
operated to be disarmed (The default value is 60 seco-
nds)
This time represents the time from the moment
when an alarm is triggered in a certain zone to the
moment when an alarm is triggered again within the
Repeat
time period, without alarming operation.
Time
Usually, this time applies to the infrared zone (The
default value is 60 seconds).
This parameter represents whether the device alarm
Remove
sounds on removal.
setting
This function allows setting of zones to be monitore-
Absent
d when user is absent. Click on the [Absent] key, sel-
setting
ect zones to be monitored on the setting interface,
and then the setting is completed.
This function allows setting of zones to be monitored
Home
when user is at home.
setting
The setting method is the same as that of the Absent
settings.
6.6 Description of volume settings
Doorbell
In this function, user can set the doorbell's ring tone,
Setting
ring volume and intercom volume of the doorbell.
6.7 Description of password settings
The user's password can be set on this interface.
User
The default password is 123456.
password
15