    Table of Contents Chapter 1: Before You Start Package Contents Synology RX1222sas at a Glance LED Indicator Table Hardware Specification Spare Parts Optional Accessories Safety Instructions Chapter 2: Hardware Setup Tools and Parts for Component Installation Install Storage Drives Install and Remove Rail Kits...
  • Page 3: Package Contents

    Chapter Before You Start Thank you for purchasing this Synology product! Before setting up your new expansion unit, please check the package contents to verify that you have received the items below. Also, make sure to read the safety instructions carefully to avoid harming yourself or damaging your expansion unit.
  • Page 4: Synology Rx1222Sas At A Glance

    Rail Kit Release Tab lock. RX1222sas automatically powers on when the power cord is plugged into the power source. For more information, please see "Connect with Synology NAS". For more information about the rail kit installation, please refer to the Quick Installation Guide that comes with the rail kit.
  • Page 5 "LED Indicator Table". Expansion Unit ID Indicates the ID number of the expansion unit. Indicator Connects to the SAS OUT port of a Synology NAS or another SAS IN Port and expansion unit. For more information, please see "Connect with Indicator Synology NAS".
  • Page 6: Led Indicator Table

    Synology NAS disconnected Note: 1 Please try to restart your Synology NAS or re-insert the drives, then run the HDD/SSD manufacturer's diagnostic tool to check the health status of the drives. If you can sign in to DSM, please run the built-in S.M.A.R.T.
  • Page 7: Hardware Specification

    Hardware Specification Item RX1222sas Compatible Drive Type 3.5"/2.5" SATA/SAS x 12 • SAS IN x 1 Expansion Port • SAS OUT x 1 • 88 x 430.5 x 692 Size (H x W x D) (mm) • 88 x 482 x 724 (with server ears) Weight (kg) 13.5...
  • Page 8: Spare Parts

    External MiniSAS HD Cable Cable MiniSASHD_EXT_2 200 cm Optional Accessories With Synology accessories, you can customize your expansion unit to fit different business environments without www.synology.com/compatibility worrying about compatibility and stability. Visit for more information. 8 Chapter 1: Before You Start...
  • Page 9: Safety Instructions

    Safety Instructions Keep away from direct sunlight and away from chemicals. Ensure a stable environment with no abrupt changes in temperature or humidity. Place the unit right side up at all times. Keep the unit away from liquids. Before cleaning, unplug the power cord. Do not use chemical or aerosol cleaners. Wipe with damp paper towels.
  • Page 10: Chapter 2: Hardware Setup

    Tools and Parts for Component Installation Please prepare below tools and parts before setting up your expansion unit: • A screwdriver • At least one 3.5"/2.5" SAS/SATA drive (please visit www.synology.com/compatibility for compatible drive models) Warning: If you install a drive that contains data, the system will format the drive and erase all existing data.
  • Page 11 2 For 2.5" drives: Place the drive in the drive tray. Turn the tray upside down and tighten the screws to secure the drive in place. 3 Insert the loaded drive tray into the empty drive bay. Note: Make sure that the drive tray is completely inserted. Otherwise, the drive might not function properly. 4 Push the handle inward to secure the drive tray.
  • Page 12: Install And Remove Rail Kits

    Install and Remove Rail Kits Here we use RKS-02 as an example to illustrate how to install or remove the rail kits. For more information about the rail kit installation, please refer to the Quick Installation Guide that comes with the rail kit. To install the rail kit 1 Loosen and remove the screws from the rack.
  • Page 13 2 Slide the front latch outward and insert the brackets into the rack holes. 3 Extend the inner rail: 1 Fully extend the inner rail outwards until you hear a click sound. 2 Pull and hold the rear latch on the inner rail, as illustrated, and continue to pull out the inner rail from the assembly.
  • Page 14 5 With the help of another person, carefully align the inner rails to the outer rail assembly, and push the chassis towards the rack. 6 Pull the front latch of the inner rail as illustrated to unlock the inner rail, and continue pushing the chassis towards the rack.
  • Page 15 To remove the rail kit 1 To remove the chassis from the rack, press the rail kit release tabs on the ear holders inward and pull the chassis out of the rack. 2 With the help of another person, carefully remove the chassis from the rack. Then, slide the inner rail attached to the chassis toward the front panel of the chassis to detach it.
  • Page 16: Connect With Synology Nas

    Connect with Synology NAS 1 Connect one end of the expansion cable to the SAS OUT port of the Synology NAS and the other to the SAS IN port of the RX1222sas. Make sure that the blue release bands of the cable face to the right when plugging it into the Synology NAS and upward when plugging it into the RX1222sas;...
  • Page 17 • Do not remove the expansion cable while the host device is still powered on. Doing so may result in data loss. 3 Press the power button on the front panel to power on your Synology NAS. The expansion unit ID of RX1222sas connected to Synology NAS will be displayed in sequence on the back panel.
  • Page 18: Chapter 3: System Maintenance

    Chapter System Maintenance Replace System Fan If a system fan malfunctions, please see the instructions below to open RX1222sas and replace the malfunctioning fan. 1 Press the small buttons located on the sides of the RX1222sas. 2 Lift to remove the fan cover.
  • Page 19: Replace Power Supply Unit (Psu)

    4 Find the malfunctioning fan. Lift up the fan to remove it. 5 Prepare a new fan and slide it into RX1222sas. Make sure that the fan is aligned properly. Replace Power Supply Unit (PSU) If a PSU or its fan malfunctions, please follow the steps below to replace the malfunctioning PSU.
  • Page 20 Section 5. License Limitations. The license set forth in Sections 1, 2 and 3 applies only to the extent that you have ordered and paid for the Product and states the entirety of your rights with respect to the Software. Synology reserves all rights not expressly granted to you in this EULA.
  • Page 21 Arbitration Law and related enforcement rules of the country in which Synology Inc. was organized. In such cases, the arbitration will be limited solely to the dispute between you and Synology. The arbitration, or any portion of it, will not be consolidated with any other arbitration and will not be conducted on a class-wide or class action basis.
  • Page 22 Section 3. Limited Warranty and Remedies 3.1 Limited Warranty. Subject to Section 3.2, Synology warrants to the Customer that each Product (a) will be free of material defects in workmanship and (b) under normal use will perform substantially in accordance with Synology's published specifications for the Product during the Warranty Period.
  • Page 23 Section 4. Limitations of Liability 4.1 Force Majeure. Synology will not be liable for, or be considered to be in breach of or default under this Warranty on account of, any delay or failure to perform as required by this Warranty as a result of any cause or condition beyond its reasonable control (including, without limitation, any act or failure to act by Customer).
  • Page 24 Arbitration Association, except as otherwise provided below. The arbitration will be conducted before a single arbitrator, and will be limited solely to the dispute between Customer and Synology. The arbitration, or any portion of it, will not be consolidated with any other arbitration and will not be conducted on a class-wide or class action basis. The arbitration shall be held in King County, Washington, U.S.A.
  • Page 25 5.9 Entire Agreement. This Warranty constitutes the entire agreement, and supersedes any and all prior agreements, between Synology and Customer related to the subject matter hereof. No amendment, modification or waiver of any of the provisions of this Warranty will be valid unless set forth in a written instrument signed by the party to be bound thereby.
  • Page 26 FCC Declaration of Conformity This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
  • Page 27 この装置は、クラス A 機器です。この装置を住宅環境で使用すると電波妨 害を引き起こすことがあります。この場合には使用者が適切な対策を講ずる よう要求されることがあります。 VCCI 一 A...

Table of Contents