Neilsen WWB-05806 Original Instructions Manual

Neilsen WWB-05806 Original Instructions Manual

Bilge pump

Advertisement

Quick Links

BILGE PUMP
CT1731
CT1732
CT1733
Ref no. WWB-05806
Ref no. WWB-05808
Ref no. WWB-06928
ORIGINAL INSTRUCTIONS
SAVE THESE INSTRUCTIONS AND PRECAUTIONS.
READ ALL PRECAUTONS AND INSTRUCTIONS BEFORE USE.
Cannon Tools Limited
Address: 20 Station Road, Rowley Regis, West Midlands, B65 0JU.U.K.

Advertisement

Table of Contents
loading

Summary of Contents for Neilsen WWB-05806

  • Page 1 BILGE PUMP CT1731 CT1732 CT1733 Ref no. WWB-05806 Ref no. WWB-05808 Ref no. WWB-06928 ORIGINAL INSTRUCTIONS SAVE THESE INSTRUCTIONS AND PRECAUTIONS. READ ALL PRECAUTONS AND INSTRUCTIONS BEFORE USE. Cannon Tools Limited Address: 20 Station Road, Rowley Regis, West Midlands, B65 0JU.U.K.
  • Page 3: Ec Declaration Of Conformity

    In case of alteration of the machine, not agreed upon by us, this declaration will lose its validity. Product description: BILGE PUMP Model: CT1731 (Ref no. WWB-05806) CT1732 ( Ref no. WWB-05808) CT1733 (Ref no. WWB-06928)
  • Page 4: Specification

    1.SPECIFICATION Model CT1731 CT1732 CT1733 Open Flow Rating 1000 GPH 2000 GPH 3000 GPH Power Source 12 Volts 12 Volts 12 Volts Current 5.5 Amps 11 Amps 13 Amps Max. Fuse 7 Amps 15 Amps 18 Amps Outlet Diameter 28.5 mm 28.5 mm 32 mm 2.
  • Page 5 a. Stay alert, watch what you are doing and use common sense when operating a pump. Do not use a pump while you are tired or under the influence of drugs, alcohol or medication. A moment of inattention while operating pumps may result in serious personal injury.
  • Page 6: Technical Description

    • Do not install or operate the submersible pump in an explosive environment or near flammable material. • Do not operate the submersible pump without liquid. • Do not run the submersible pump dry. WARNING! The submersible pump together with associated pipework operate under pressure.
  • Page 7: Unpacking And Checking

    4. UNPACKING AND CHECKING Carefully remove the product from the packaging and examine it for any sign of damage that may have happened during shipping. Lay the contents out and check them against the parts shown below. If any part is damaged or missing; please contact the seller and do not attempt to use the product.
  • Page 8 8. Wiring: • In order to prevent electrolysis and corrosion to wiring connections, its essential that all wire ends and terminals be located above the highest possible water level by fastening with insulated staples or cable ties. • Using wire that is too small, or running over an extended distance will result in excess heat in the wiring, resulting in voltage drops and lower performance of the pump.
  • Page 9: Maintenance And Storage

    of the battery. • To verify the correct direction of rotation (and thus the polarity) is correct is by looking into the inlet hole on the bottom of the pump while running and see if the impeller blades rotate in the same direction as the arrow on the base of the unit.
  • Page 10: Troubleshooting

    7. TROUBLESHOOTING Problem Possible causes Possible solutions Pump runs, 1. Screen and/or impeller 1. Remove screen. Clean out dirt clogged. and debris from screen and will not 2. When starting, the pump impeller, then replace. deliver any water 2. There must be at least 1/8" deep water.
  • Page 11 8. DISPOSAL Pumps that are no longer usable should not be disposed of with household waste but in an environmentally friendly way. Please recycle where facilities exist. Check with your local council authority for recycling advice. 9. SYMBOLS In this manual and/or on the machine the following symbols are used: Volts AMPS Direct current...
  • Page 12 CANNON TOOLS LTD Add: 20 station road, Rowley Regis, west midlands,B65 0JU.U.K. Made in China...

This manual is also suitable for:

Ct1732Ct1733Ct1731Wwb-05808Wwb-06928

Table of Contents