The VEP4600 comes from the factory with one or two PSUs and four or five AC normal fan modules installed in the platform, depending
on the configuration. The fan modules and the power supplies, which have integrated fans, are hot-swappable.
In addition to the power supply modules, you can order and install fan modules separately.
The VEP4600 supports airflow is from the I/O panel to the PSU. The red indicator is the normal airflow direction.
Environmental factors can decrease the amount of time required between fan replacements. Check the environmental factors regularly.
An increase in temperature and/or particulate matter in the air might affect performance; for example, new equipment installation.
CAUTION:
Check the fans at six-month intervals; replace them as necessary. Regularly monitor the speeds of the fans
to accurately determine replacement intervals.
Topics:

Components

Fan module installation

Components
Figure 15. VEP4600 fan modules
1. Fan modules
Fan LEDs
Solid green—Fan function is normal.
Flashing yellow (amber)—There is a fan fault.
Off—Fan is off.
Fan module installation
The fan modules in the VEP4600 are field replaceable. Module slot 1 is on the left side of the platform; module slot 5 is on the right side of
the platform.
1. Take the fan module out of the shipping box.
2. Slide the module into the bay.