Ground lug

Dell EMC recommends you ground your switch; however, grounding is optional and the ground lug assembly kit is not included with the
switch. The ground lug must be a UL-recognized, crimp-type lug. To order a UL-certified ground lug with bracket, contact your Dell EMC
sales representative.
NOTE:
The ground cable is not included with the switch.
NOTE:
For AC-powered platforms, although the third conductor of the AC power cord provides a ground path, Dell EMC
recommends grounding your platform with a dedicated ground wire.
To attach a ground lug assembly to the switch, use the included two M3 ground lug bracket screws. The switch ships with the M3 ground
lug bracket screws attached.
CAUTION:
Grounding conductors
NOTE:
Coat the one-hole lug with an anti-oxidant compound before crimping. Also, bring any unplated mating surfaces
to a clean finish and coat with an antioxidant before mating. Plated mating surfaces must be clean and free from
contamination.
NOTE:
The rack installation ears are not suitable for grounding.
Before you install the switch into the dual-tray:
1. Cut the ground cable (not included) to the desired length. The cable length must facilitate proper operation of the fault interrupt
circuits. Use the shortest cable route allowable.
2. Unscrew the two attached M3 screws and set aside.
3. Attach the ground lug and bracket to the switch using the M3 screws.
Order a UL-certified GND lug with bracket separately.
Figure 6. VEP4600 ground lug attached
4. Attach the other end of the ground cable to a suitable ground point such as the rack or cabinet.

Rack or cabinet hardware installation

You may either place the platform on a rack shelf or mount the platform directly into a 19" wide, EIA-310- E-compliant rack.
The platform includes two-post rail assemblies.
WARNING:
This document is a condensed reference. Read the safety instructions in your
Regulatory information booklet before you begin.
NOTE:
The illustrations in this document are not intended to represent a specific platform.
18
VEP4600 installation
must be made of copper. Do not use aluminum conductors.