Installation Diagram Of Indoor & Outdoor Unit - Haier AU302CHBAA Installation Instructions Manual

Outdoor unit
Table of Contents

Advertisement

Installation diagram of indoor & outdoor unit
Outdoor unit
Piping data.
Liquid pipe
Gas pipe
Pipe length of one way
Drop between indoor
and outdoor unit
No need to recharge: when piping length of one way is less than 5 meters.
1
L1 means the piping length when the system only connects with one indoor unit.
2
L2, L3 means the piping length when the system connects with 2 indoor units.
3
Long piping length and large drop between indoor unit and outdoor unit will reduce the
performance capacity obviously.
L1
L2
L3
mm
mm
1
L1
m
Suggest 10m Max. :15m
2
L2
m
Suggest 10m Max. :15m
2
L3
m
Suggest 10m Max. :15m
Indoor unit up
m
Suggest 5m
Indoor unit down
m
4
A
AS122XABAA
B 1
AS092XABAA
B 2
AS092XABAA
6.35
12.7
3
3
3
Max. :10m
3
3
Suggest 5m
Max. :10m