3. Pull out the starter rope approximately 30 cm/12 in
and put it in the notch on the pulley.
4. Let the pulley rotate slowly rearward to release the
recoil spring.
5. Remove the center screw and remove the pulley.
WARNING:
when you replace the return spring or
the starter rope. The recoil spring is in
tension when it is wound up in the starter
housing. If you are not careful, it can
eject and cause injuries. Use protective
glasses and protective gloves.
6. Remove the used starter rope from the handle and
the pulley.
7. Attach a new starter rope to the pulley. Wind the
starter rope approximately 3 turns around the pulley.
8. Pull the starter rope through the hole in the starter
housing and the starter rope handle.
9. Attach the center screw in the center of the pulley.
26
You must be careful
10. Make a tight knot at the end of the starter rope.
To tighten the recoil spring
1. Put the starter rope into the notch in the pulley.
2. Turn the starter pulley approximately 2 turns
clockwise.
3. Make sure that you can turn the pulley ½ turn after
the starter rope is fully extended.