CHAPTER 2 INSTALLATION
Installation for Main Site

BUS Cable Connection

(1) Cable Connection Between BUS Connector on the BWB and DAIA/DAID Card
Connect the DAIA/DAID card to the BUS connector on the BWB by the RMT BUS CA-A, as
shown in
Figure
In BUS connector on the BWB, BUS1B or BUS0B of the even-numbered PIMs (PIM0, 2, 4,
etc.) must be used for this connection.
(a) When mounting DAIA/DAID card on PIM0
• When Main PIM is 1 or 2 PIM configuration
PIM0
• When Main PIM is 3 or 4 PIM configuration
PIM0
NOTE:
DAIA/DAID card must be mounted in even-numbered PIMs. When mounted in
PIM0 BWB BUS connector, BUS1B or BUS0B may be used for this connection.
When mounted in PIM2 or PIM4 BWB BUS connector, BUS1B must be used.
Page 24
2-4.

Figure 2-4 BUS Cable Connection (1 of 2)

BUS1B
BUS1A
PCM1
PCM0
DAIA/
BUS0B
DAID
BUS0A
BUS1B
BUS1A
PCM1
PCM0
DAIA/
BUS0B
DAID
BUS0A
NOTE
RMT BUS CA-A
PIM0
NOTE
PIM2
RMT BUS CA-A
PIM0
NEAX2000 IVS
PIM0
2 PIM
1 PIM
PIM2
PIM0
4 PIM
3 PIM