Electrical Requirements
You can check the parameters of
adjustment setting for this
appliance on the rating plate.
Refer to the Technical data
chapter.
The manufacturer declines any
liability if these safety measures
are not observed.
This hob is designed to be connected to a
220-240 V 50-60 Hz AC electrical supply.
Before switching on, make sure the
electricity supply voltage is the same as that
indicated on the hob rating plate. The rating
plate is located below the surface of the
casing.
The hob is supplied with a 3 core flexible
supply cord.
Upon completion there must be no cut, or
stray strands of wire present and the cord
clamp must be secure over the outer sheath.

Gas connection

Warning! Refer to Safety
chapters.
Caution! Information for
authorised installer only.
Connection to main pipe
Warning! This appliance is not
connected to a combustion
products evacuation device.
Before you proceed with the
installation, make sure that the
local distribution conditions,
nature of the gas and gas
pressure, and the adjustment of
the appliance are compatible.
The installation must be compliant with the
current local regulations. Complying with the
local regulations, the connection of the
Replacement of the connection cable
Warning! To replace the
connection cable, the technician
must have a specific equipment.
In this case, only cable type H03V2V2-F T90
must be used. The cable section must be
suitable to the voltage and the working
temperature. The yellow and green earth
wire
2
must be approximately 2 cm longer
than the brown or black phase wire
cooktop to the gas pipe network or gas
cylinder must be made by means of a rigid
copper or steel pipe with fittings, or by
means of a continuous surface stainless
steel hose.
If there is a problem with the
pipe, do not repair it yourself.
Contact the local After Sales
Service Provider. Refer to the
Service chapter.
The connection must be installed correctly
and fixed into the hob connection pipe.
Otherwise, gas may leak from the
connection pipe.
Warning! When you finish the
installation, check the sealing and
pipe fixing. To check the
installation, use soapy water. Do
not use the flame.