Fisher FSAI-Pro-92AE2 Service Manual page 51

Split wall-mounted type
Table of Contents

Advertisement

For other motors:
NO.
1
Color
Orange
Signal
Hu
Color
Red
Signal
W
1) Release the UVW connector. Measure the resistance of U-V, U-W, V-W. If the resistance is not
equal to each other, the fan motor must has problems and need to be replaced. Otherwise, go to
step 2.
2) Power on and when the unit is in standby, measure the voltage of pin4-5 in feedback signal
connector. If the value is not 5V, change the PCB. Otherwise, go to step 3.
Index2:
1: Indoor AC Fan Motor
Power on and set the unit running in fan mode at high fan speed. After running for 15 seconds,
measure the voltage of pin1 and pin2. If the value of the voltage is less than 100V(208~240V power
supply)or 50V(115V power supply), the PCB must has problems and need to be replaced.
2. Indoor or Outdoor DC Fan Motor(control chip is in fan motor)
Power on and when the unit is in standby, measure the voltage of pin1-pin3, pin4-pin3 in fan motor
connector. If the value of the voltage is not in the range showing in below table, the PCB must has
problems and need to be replaced.
2
3
Grey
White
Hv
Hw
Blue
Yellow
V
U
51
4
5
Pink
Black
Vcc
GND

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fsoai-pro-92ae2Fsai-pro-122ae2Fsoai-pro-122ae2

Table of Contents