Supported Fiber Optic Cables; Tamper-Evident Security Seals - Siemens SIMATIC NET RUGGEDCOM RSG2200F Installation Manual

Rugged ethernet switches
Hide thumbs Also See for SIMATIC NET RUGGEDCOM RSG2200F:
Table of Contents

Advertisement

Follow these recommendations for copper data cabling in high electrical noise
environments:
1.5.3

Supported Fiber Optic Cables

The following fiber optic cable types are supported under the stated conditions.
Cable Type
Wavelength (nm) Modal Bandwidth
OM1 (62.5/125)
OM2 (50/125)
a
OM3 (50/125)
a
OM4 (50/125)
a
Laser optimized.
1.6

Tamper-Evident Security Seals

In compliance with the security requirements of the Federal Information Processing
Standards (FIPS140-2), FIPS-compliant tamper-evident security seals are applied
to potential access points on this device. Security seals provide evidence of
unauthorized tampering or removal of components.
Worn, damaged or missing seals must be replaced immediately.
Replacement seals are available for purchase from Siemens. For more information,
contact a Siemens Sales representative.
There are three ways to determine if a security seal has been tampered with:
RUGGEDCOM RSG2200F
Installation Manual, 04/2022, C79000-G8976-1346-10
Data cable lengths should be as short as possible, preferably 3 m (10
ft) in length. Copper data cables should not be used for inter-building
communications.
Power and data cables should not be run in parallel for long distances, and
should be installed in separate conduits. Power and data cables should intersect
at 90° angles when necessary to reduce inductive coupling.
Shielded/screened cabling can be used when required. Care should be taken to
avoid the creation of ground loops with shielded cabling.
(MHz·km)
850
200
1300
500
850
500
1300
500
850
1500
1300
500
850
3500
1300
500
NOTICE
The seal is cut or torn
A pattern is left on the device when the top layer of the seal is removed
1.5.3 Supported Fiber Optic Cables
Distance (m)
100Base-FX
1000Base-SX
275
2000
550
2000
550
2000
550
2000
Introduction
10GBase-SR
33
82
300
400
5