Miter Detent System - Adjustment Procedure - Bosch GCM18V-10SD Operating/Safety Instructions Manual

Hide thumbs Also See for GCM18V-10SD:
Table of Contents

Advertisement

Available languages

Available languages

Miter Detent System – Adjustment
Procedure
Calibrating Miter Detent System
1. Engage the miter detent at the 0° position.
Loosen the miter lock knob (Fig. 14, 20) 1/2
turn.
2. Loosen the 4 screws holding the detent
plate (Fig. 17, 31) using the Torx wrench
(Fig. 7, 41).
Fig. 17
31
31
3. Lock head assembly down using the head as-
sembly lock pin (Fig. 14, 8).
4. Hold one side of a 90° combination square
against the fence (Fig. 18, 12) and rotate
the table (22) and detent plate (17) until the
side of the saw blade is in full contact with
the other side of the square.
5. Tighten all four screws. Then loosen and re-
set the miter scale pointer to the "0" posi-
tion (Fig. 18).
Miter Scale Pointer Adjustment
1. Rotate table (Fig. 19, 22) to 0° position and
lock in place.
2. Raise the head assembly (Fig. 20, 28) to the
full UP position.
3. Loosen the pointer adjust screw that holds
the miter scale pointer (Fig. 19, 19) in place.
16099221PJ GCM18V-10SD OSI 20220506.indd 24
Adjustments
Fig. 18
Combination
Fig. 19
31
31
4. Position the pointer to align with the 0° line.
Tighten the screw.
-24-
Contacting
blade
12
22
0° Miter
Detent
square
Pointer
Adjust
Screw
22
19
0° Line
17
5/6/22 11:42 AM

Advertisement

Table of Contents
loading

Table of Contents