Connecting The Receiver To A Control Panel - Interlogix 60-660-43 Installation Sheet

Table of Contents

Advertisement

4.
Slide the DIP switch down to put the receiver in run
mode.
To delete a keychain touchpad from the receiver, repeat the
procedure for each button on a keychain touchpad button
that is learned into a zone. A keychain touchpad is deleted
only when all learned buttons are deleted from their
respective zones.
Zone/trouble outputs N/O or N/C
All eight zones and both trouble outputs default to N/C, and
can be changed to N/O.
To program a zone output N/O or N/C, do the following:
1.
To enter program mode, slide the DIP switch up.
2.
Press the tamper switch once to gain access to
configuring zone outputs. The low battery LED should
turn on or flash.
3.
Press and release the ADV switch until the desired zone
LED turns on.
4.
Press and release the SEL switch to change the output
configuration to the desired setting. (zone LED on = N/C,
zone LED off = N/O).
5.
Repeat the procedure for each zone configuration
change.
6.
Slide the DIP switch down to return to run mode.
To program both trouble outputs N/O or N/C, do the
following:
1.
To enter program mode, slide the DIP switch up.
2.
Press the tamper switch once to gain access to
configuring zone outputs.
3.
Press and release the ADV switch until all zone LEDs
are off (nine presses) to select the trouble outputs.
4.
Press and release the SEL switch to change the trouble
outputs configuration to the desired setting (low battery
LED on = N/C, low battery LED flashing = N/O).
5.
Slide the DIP switch down to return to run mode.
RF supervision
All eight zones default to RF supervised, and can be
changed to be unsupervised.
To enable or disable RF supervision on a zone, do the
following:
1.
To enter program mode, slide the DIP switch up.
2.
Press the tamper switch twice to gain access to
configuring zone supervision.
3.
Press and release the ADV switch until the desired zone
LED turns on.
4.
Press and release the SEL switch to change the RF
supervision configuration to the desired setting.
P/N 466-1452 • REV E • ISS 16OCT18
5.
Repeat the procedure for each zone configuration
change.
6.
Slide the DIP switch down to return to run mode.
Note: Keychain touchpads are not supervised. Panic button
transmitters learned into zone 1 are not supervised.
Keychain touchpad zone output
responses
Zone outputs 3 through 6 can be set up to respond by
switching momentarily or to maintain (toggle on/off for each
activation).
To change the zone output response to momentarily or
maintain, do the following:
1.
To enter program mode, slide the DIP switch up.
2.
Press the tamper switch twice to gain access to
configuring zone outputs.
3.
Press and release the ADV switch until the desired zone
LED (3 to 6) turns on.
4.
Press and release the SEL switch to change the zone
output response to the desired setting. The LED for the
selected zone should turn off (maintained) or on
(momentarily), indicating the current configuration.
5.
Advance to another programmable option or slide the
DIP switch down to return to run mode.
Connecting the receiver to a
control panel
There are four ways to wire the loop receiver to the control
panel.
Figure 9: Supervised N/O loop wiring diagram shows a
wiring diagram for a supervised N/O loop.
Figure 9: Supervised N/O loop wiring diagram
Receiver terminals
EOL resistor
Note: You can connect multiple normally open (N/O) loop
receiver zone outputs in parallel to panel zone inputs.
Figure 10: N/C loop wiring diagram shows a wiring diagram
for an N/C loop.
Panel +12V
Panel GND
Return
Zone 1
Panel terminals
7 / 10

Advertisement

Table of Contents
loading

This manual is also suitable for:

60-660-43-eurRxi4n8