Oil conserving fryer electric fryers
Table of Contents

Advertisement

2. Open the control panel by removing the screws on the bottom of the bezel. Carefully lower the
bezel.
3. Remove the two screws from the upper corners of the control panel and allow the control panel to
swing down.
4. Unplug the wiring harnesses and disconnect the grounding wires from the terminals on the back of
the controller. Remove the control panel assembly by lifting it from the hinge slots in the control
panel frame.
5. Disconnect the wiring from the component to be replaced, being sure to make a note of where each
wire was connected.
6. Dismount the component to be replaced and install the new component, being sure that any
required spacers, insulation, washers, etc. are in place.
NOTE: If more room to work is required, the control panel frame assembly may be removed by
removing the hex-head screws, which secure it to the fryer cabinet (see illustration below). If this
option is chosen, all control panel assemblies must be removed per steps 1 and 2 above. The cover
plate, on the lower front of the component box, may also be removed to allow additional access if
desired. Removing the component box itself from the fryer is not recommended due to the difficulty
involved in disconnecting and reconnecting the oil-return valve rods, which pass through openings
in the component box.
7. Reconnect the wiring disconnected in step 5, referring to your notes and the wiring diagrams on
the fryer door to ensure that the connections are properly made. Also, verify that no other wiring
was disconnected accidentally during the replacement process.
8. Reverse steps 1 through 4 to complete the replacement and return the fryer to service.
Remove these three
screws at each end.
Removing the Control Panel Frame and Top Cap Assembly
1-2
Remove these two screws
from the center supports.