2.1
Different table of features
The following table indicates main different points between models HR-S6970AA,HR-S6970AG,HR-S6970AH and HR-S6970AJ.
POWER PLUG
CONVERSION PLUG
BROADCASTING STANDARD
RF OUT CH/RF OUT SYSTEM [INITIAL]
VCR PLUS+
OSD LANGUAGES
NOTE:
Mark <-- is same as left.
2.2
Service position
This unit has been designed so that the Mechanism and Main
board assemblies can be removed together from the chassis as-
sembly. Before diagnosing or servicing the circuit boards, take
out the major parts from the chassis assembly.
2.2.1 How to set the "Service position"
(1) Refer to the disassembly procedure and perform the disas-
sembly of the major parts before removing the Mechanism
assembly.
(2) Remove the screws that fix the Mechanism assembly to
the Chassis assembly. If any other screws are used to fix
the boards, remove them also.
(3) Remove the combined Mechanism and Main board assem-
blies.
(4) If any other major parts are used, remove them also.
(5) Connect the wires and connectors of the major parts that
have been removed in steps (1) to (4). (Refer to Fig. 2-2a.)
(6) Place the combined Mechanism, Main board and other
board assemblies upside down.
(7) Insert the power cord plug into the power outlet and then
proceed with the diagnostics and servicing of the board as-
sembly.
SECTION 2

SPECIFIC SERVICE INSTRUCTIONS

HR-S6970AA
AS/NZS
CEE
NOT USED
B/G,D/K,I
28-60[36]G[H]KI
28-60[36][G]HKI
G-CODE
G-CODE/SHOWVIEW
ENGLISH
ENGLISH, CHINESE
HR-S6970AG
HR-S6970AH
HK3PIN
<--
<--
B/G,D/K,I,M
28-60[36][G]HKMI
G-CODE
Notes:
• Before inserting the power cord plug into the power out-
let, make sure that none of the electrical parts are able
to short-circuit between the workbench and the board
assembly.
• For the disassembly procedure of the major parts and
details of the precautions to be taken, see "3.1 Remov-
ing the major parts".
• If there are wire connections from the Main board and
Mechanism assemblies to the other major parts, be sure
to remove them (including wires connected to the major
parts) first before performing step (2).
• When carrying out diagnosis and repair of the Main
board assembly in the "Service position", be sure to
ground both the Main board and Mechanism assem-
blies. If they are improperly grounded, there may be
noise on the playback picture or FDP counter display
may move even when the mechanism is kept in an inop-
erative status.
• In order to diagnose the playback or recording of the
cassette tape, set the Mechanism assembly to the re-
quired mode before placing it upside down. If the mech-
anism mode is changed (including ejection) while it is in
an upside down position the tape inside may be dam-
aged.
• For some models, the mechanism and board assem-
blies are attached by connectors only. When carrying
out a diagnosis or repair of the boards in the "Service
position", make sure that the connectors are not dis-
connected.
TP2253
A.PB.FM
TP4001
CTL.P
TP111
D.FF
TP106
PB.FM
TP2254
A.REC
Fig.2-2a
HR-S6970AJ
SASO
<--
PROVIDED
<--
<--
G-CODE/SHOWVIEW
<--
<--
Main board
assembly
(No.YD047)1-5