2.1
DIFFERENT TABLE OF FEATURE
The following table indicates main different points between models HR-V210EX/EY/EZ and HR-V510EX/EY/EZ.
VIDEO HEAD
HiFi HEAD
SQPB
RECORDING & PLAYBACK SPEED
16:9
AV OUTPUT TERMINAL
STEREO DECODER
AUTO SP → LP TIMER
NOTE:
Mark ← is same as left.
2.2
Service position
This unit has been designed so that the Mechanism and Main
board assemblies can be removed together from the chassis as-
sembly. Before diagnosing or servicing the circuit boards, take
out the major parts from the chassis assembly.
2.2.1 How to set the "Service position"
(1) Refer to the disassembly procedure and perform the disas-
sembly of the major parts before removing the Mechanism
assembly.
(2) Remove the screws that fix the Mechanism assembly to
the Chassis assembly. If any other screws are used to fix
the boards, remove them also.
(3) Remove the combined Mechanism and Main board assem-
blies.
(4) If any other major parts are used, remove them also.
(5) Connect the wires and connectors of the major parts that
have been removed in steps (1) to (4). (Refer to Fig. 2-2a.)
(6) Place the combined Mechanism, Main board and other
board assemblies upside down.
(7) Insert the power cord plug into the power outlet and then
proceed with the diagnostics and servicing of the board as-
sembly.
Notes:
• Before inserting the power cord plug into the power out-
let, make sure that none of the electrical parts are able
to short-circuit between the workbench and the board
assembly.
• For the disassembly procedure of the major parts and
details of the precautions to be taken, see "3.1 Remov-
ing the major parts".
• If there are wire connections from the Main board and
Mechanism assemblies to the other major parts, be sure
to remove them (including wires connected to the major
parts) first before performing step (2).
• When carrying out diagnosis and repair of the Main
board assembly in the "Service position", be sure to
ground both the Main board and Mechanism assem-
blies. If they are improperly grounded, there may be
noise on the playback picture or FDP counter display
may move even when the mechanism is kept in an inop-
erative status.
SECTION 2

SPECIFIC SERVICE INSTRUCTIONS

HR-V210EX/EY/EZ
2 HEAD
NOT USED
NOT USED
SP
NOT USED
NOT USED
NOT USED
NOT USED
• In order to diagnose the playback or recording of the cas-
sette tape, set the Mechanism assembly to the required
mode before placing it upside down. If the mechanism
mode is changed (including ejection) while it is in an up-
side down position the tape inside may be damaged.
• For some models, the mechanism and board assem-
blies are attached by connectors only. When carrying
out a diagnosis or repair of the boards in the "Service
position", make sure that the connectors are not dis-
connected.
C3018
TIMER
CLOCK
TP411
D.FF
TP4001
CTL.P
TP2253
TP106
A.PB.FM
PB FM
Fig.2-2a
2.3
Jig RCU mode
This unit uses the following two modes for receiving remote con-
trol codes.
(1) User RCU mode:Ordinary mode for use by the user.
(2) Jig RCU mode: Mode for use in production and servicing.
When using the Jig RCU, it is required to set the VCR to the Jig
RCU mode (the mode in which codes from the Jig RCU can be
received). As both of the above two modes are stored in the EE-
PROM, it is required to set the VCR back to the User RCU mode
each time that an adjustment is made or to check that the neces-
sary operations have been completed.These modes can be set
by the operations described below.
User RCU mode
HR-V510EX/EY/EZ
4 HEAD
USED
USED
SP/LP
USED (PLAYBACK)
AUDIO L/R
NICAM/A2
USED
Main board
assembly
Jig RCU mode
( : not displayed)