Specifications Of Electrical Parts - Toshiba RAS-B05BKVG-E Service Manual

Hide thumbs Also See for RAS-B05BKVG-E:
Table of Contents

Advertisement

6-1. Indoor Unit
No.
1
Fan Motor (for indoor)
2
Room temp. sensor (TA-sensor)
3
Heat exchanger temp. sensor (TC-sensor)
4
Heat exchanger temp. sensor (TCJ-sensor)
5
Louver motor
6-2. Outdoor Unit
No.
1
Compressor
2
Fan Motor
3
Pulse Modulating Valve (PMV) coil
4
4-Way valve coil
5
Reactor
6
Suction temp. sensor
7
Discharge temp. sensor
8
Outside air temp. sensor
9
Heat Exchanger temp. sensor
10
Terminal block

6. SPECIFICATIONS OF ELECTRICAL PARTS

Parts name
RAS-B05, 07, 10, 13
RAS-B16
Parts name
RAS-05, 07
RAS-10, 13
RAS-16
RAS-05, 07,16
RAS-10,13
RAS-16
(TS sensor)
(TD sensor)
(TO sensor)
(TE sensor)
(5 poles)
Type
ype
SJM-240-25
SJM-240-35
(-)
(-)
(-)
24BYJ48A-080
Type name
NX66F0F-20D
KSK89D53UEZ
KSN108D22UFZ
WDF-340-A43-1
ICF-140-43-4R
PQ-M10012-000313
DXQ-939
CH-69-Z-T
(Inverter attached)
(Inverter attached)
(Inverter attached)
(Inverter attached)
JXO-5B
- 23 -
- 23 -
FILE NO. SVM-18006
FILE NO. SVM-18006
Specificat
AC 220~240V, 25W
AC 220~240V, 35W
10kΩ at 25°C
10kΩ at 25°C
10kΩ at 25°C
Output (Rated) 4 phase, DC12V
Specifications
3-Phases (6-Poles) ;
630W
3-Phases (6-Poles) ;
712W
3-Phases (6-Poles) ;
840W
DC 140-340V ; 43W
DC 140-340V ; 43W
DC 12V
AC 220-240V
L = 19mH, 10A
10kΩ at 25°C
62kΩ at 20°C
10kΩ at 25°C
10kΩ at 25°C
AC 250V, 20A

Advertisement

Table of Contents
loading

Table of Contents