. Â NOTE Information that requires special emphasis . Â TIP Alternate techniques or clarifying information. SHALL: This word is understood to be mandatory . SHOULD: This word is understood to be advisory . Sentry Equipment Corp...
High pressures! This equipment may contain fl uids at very high pressures . Prior to installing, removing or maintaining this equipment, ensure that the equipment is isolated from all connecting piping, the equipment is depressurized, the contents have been drained, and the equipment is cool . Saf-T-Vise STV-LP1 & Saf-T-Vise STV-LP2...
Installation The Saf-T-Vise STV-LP1 and Saf-T-Vise STV-LP2 tool holders attach to a pipeline isolation valve by means of either a flanged or NPT threaded connection . A holder is installed or removed during the operation and maintenance of the equipment as detailed in the following sections .
Operation The Saf-T-Vise STV-LP1 and Saf-T-Vise STV-LP2 tool holders are hand insertable and retractable and do not require a separate insertion and retraction tool . Read instructions thoroughly before installing or using equipment . Contact your representative or factory customer service if you have any questions .
Page 8
Tighten the locking collet bolt to 35 ft-lb (47 .45 Nm) . This torque will hold a rod/shaft securely up to the design pressure of the unit . 6. Install safety chain through the chain holder; do not leave any slack in the chain . Sentry Equipment Corp...
4. Open the bleeder valve to relieve any trapped pressure . Support the rod/shaft during removal from the process isolation valve to prevent bending . 5. Remove the holder from the process isolation valve . Saf-T-Vise STV-LP1 & Saf-T-Vise STV-LP2...
4. When the exposed rod/shaft is cleaned of external debris, wipe the rod/shaft with a clean rag and solvent to remove any leftover debris . 5. Slide the rod/shaft to the fully retracted position and repeat the steps above to clean the remaining rod/shaft . Sentry Equipment Corp...
Loosen (but not completely remove) the small set screw on the upper body . Make sure the set screw is loose . Failure to loosen the set screw can cause permanent damage to the holder . Saf-T-Vise STV-LP1 & Saf-T-Vise STV-LP2...
Page 12
. If installing a new rod/shaft, wipe the new rod/shaft down with solvent and a clean rag to remove any debris . Sentry Equipment Corp...
Page 13
If re-installing a used shaft, tighten down to the mark made earlier . If installing a new shaft, align the mark on the fluid adapter with the outlet of the atomizer tip or quill . Saf-T-Vise STV-LP1 & Saf-T-Vise STV-LP2...
If leak persists, continue with the next step . 3. If the leak persists at a particular point, close the isolation valve, relieve pressure with bleeder valve, and contact your representative or factory customer service . Sentry Equipment Corp...
Page 15
3. Follow the procedure for Prepping a Holder for Reinstallation . – This procedure can be used for all connection points on a holder including the fluid inlet assembly, probe shaft adapters, bleeder valves, and any other connections that may be on the holder . Saf-T-Vise STV-LP1 & Saf-T-Vise STV-LP2...
– A worn collet will not distribute pressure evenly on the rod/shaft and may cause damage . – If the collet is worn, the entire holder must be replaced immediately . Collets are matched to a body assembly during manufacturing and cannot be replaced separately . Sentry Equipment Corp...
Field Service & Retrofi ts—When a problem needs immediate attention . Replacements Parts & Consumables—Order your replacement parts and consumables . Sentry ProShield Services—Select from four ProShield Guardian service plans providing diff erent levels of support to protect your large system investments with regularly scheduled maintenance .
Page 18
This page is intentionally left blank . Sentry Equipment Corp...
Page 19
This page is intentionally left blank . Saf-T-Vise STV-LP1 & Saf-T-Vise STV-LP2...
Page 20
Serving customers in more than 50 countries across six continents worldwide. sentry-equip.com 966 Blue Ribbon Circle North, Oconomowoc, WI 53066 U.S.A. | +1-262-567-7256 | support@sentry-equip.com...