Command transmission method
Transmit in the following command format
Transmitted data
Header
'0'
0x30
0x30
1 byte
1 byte
Received data
Header
'0'
0x30
0x30
1 byte
1 byte
Error response
Error message
"ERR1"
"ERR2"
"ERR3"
"ERR4"
"ERR5"
4 bytes
64
English
Data part
Control
command
'0'
(ASCII
character
string)
Undefined
Data part
Control
command
'0'
(ASCII
character
string)
Undefined
: Undefined control
command
: Out of parameter
range
: Busy status or
reception invalid
period
: Timeout or reception
invalid period
: Wrong data length
PJLink protocol
The unit's Network function is compatible with PJLink
Class 1. The following operations can be performed from
a computer when PJLink protocol is used.
Last
terminal
●
Setting the Display
symbol
●
Querying the Display status
Supported commands
(CR)
The commands to control the unit with PJLink protocol
are as follows.
0x0d
Command
POWR
1 byte
POWR?
Last
terminal
symbol
INPT
(CR)
0x0d
1 byte
INPT?
Last
terminal
symbol
AVMT
(CR)
0x0d
1 byte
AVMT?
Control
Power control
0: Standby
1: Power On
Power status query
0: Standby
1: Power On
Input switch
11: PC IN input (PC)
21: VIDEO input (VIDEO)
31: HDMI 1 input (HDMI1)
32: HDMI 2 input (HDMI2)
33: DVI-D IN input (DVI-D)
41: USB input (USB)
Input switch query
11: PC IN input (PC)
21: VIDEO input (VIDEO)
31: HDMI 1 input (HDMI1)
32: HDMI 2 input (HDMI2)
33: DVI-D IN input (DVI-D)
41: USB input (USB)
Shutter control
10: Picture On
(picture mute deactivated)
11: Picture Off
(picture on mute)
20: Audio On
(audio mute deactivated)
21: Audio Off
(audio on mute)
30: Shutter mode Off
(picture and audio mute
deactivated)
31: Shutter mode On
(picture and audio on mute)
Shutter control query
11: Picture Off (picture on mute)
21: Audio Off (audio on mute)
30: Shutter mode Off
(picture and audio mute
deactivated)
31: Shutter mode On
(picture and audio on mute)