Locating the Water Heater continued-
These materials are corrosive at very low concentration levels with little or no
odor to reveal their presence. NOTE: DAMAGE TO THE WATER HEATER
CAUSED BY EXPOSURE TO CORROSIVE VAPORS IS NOT COVERED
BY THE WARRANTY. DO NOT OPERATE THE WATER HEATER IF
EXPOSURE HAS OR WILL OCCUR. DO NOT STORE ANY
POTENTIALLY CORROSIVE COMPOUNDS IN THE VICINITY OF THE
WATER HEATER.
This water heater must be located in an area where leakage of the tank or
water line connections and the combination temperature and pressure relief
valve will not result in damage to the area adjacent to the water heater or to
lower floors of the structure. When such locations cannot be avoided, a
suitable drain pan must be installed under the water heater. The drain pan
must have a minimum length and width of at least 4 in. (10.2 cm) greater
than the diameter of the water heater. The drain pan, as described above,
can be purchased from your plumbing professional. The drain pan must be
piped to an adequate drain. The piping must be pitched for proper drainage.
1. Minimum clearance to combustible material is 0 inches for the Top,
Sides, Front, and Rear of this water heater. However, it is
recommended that at least 18 inches (45.7 cm) from the Top, and
24 inches (61 cm) from the Front. Clearance for servicing may be
reduced down to minimum clearance to combustible material, but
service time and effort may be greatly increased.
2. Increase distances to provide clearances for servicing.
Note: For California installation this water heater must be braced,
anchored, or strapped to avoid falling or moving during an earthquake.
See instructions for correct installation procedures. Instructions may
be obtained from the DSA Headquarters Office, 1102 Q Street, Suite
5100, Sacramento, CA 95811.

Water Connections

NOTE: BEFORE PROCEEDING WITH THE INSTALLATION, CLOSE THE
MAIN WATER SUPPLY VALVE.
After shutting the main water supply valve, open a faucet to relieve the water
line pressure to prevent any water from leaking out of the pipes while making
the water connections to the water heater. After the pressure has been
relieved, close the faucet. The COLD water inlet and HOT water outlet are
identified on top of the water heater. The fittings at the cold water inlet and
hot water outlet are dielectric waterway fittings with 3/4" NPT tapered male
threads. Make the proper plumbing connections between the water heater
and the plumbing system in the house. Install a shut-off valve in the cold
water supply line.
CLEARANCES
5