INSTALLATION INSTRUCTIONS
Figure 10
Unconverted Factory Configuration as viewed in the Horizontal Right Orientation
Remove plug from
collector box.
DO NOT DISCARD.
NOTE: Remove knockout in
casing before re−installing the
condensate trap.
Attach condensate
trap with screw to
collector box.
Install plug on
open port of
collector box
14
Representative drawing only, some models may vary in appearance.
Horizontal Right Trap Configuration
Representative drawing only, some models may vary in appearance.
Specifications subject to change without notice.
Gas Furnace: (F/G)9MVE
If alternate vent position
is required, loosen clamp
on inlet of vent elbow.
Remove the screw that secures
the trap to the collector box and
remove trap.
Slide relief tube in stand−offs
to adjust length.
Vent elbow shown in alternate
orientation. Tighten clamp on
inlet to vent elbow 15 lb.−in.
Align trap over middle and
right−hand port on collector box.
A11573LA
A11573LB
440 01 4401 02