Chapter 5
Certification
Test
IEC 529 (IP65/IP67)
IEC 60068-2-6
IEC 60068-2-64
IEC 60068-2-29
IEC 60068-2-32
Nebs: GR63
IEC 60068-2-30
30
Description
Water (Rain)
Sine Vibration
Random Vibration (Class 4M5)
Random Vibration
Shock (Class 4M5)
Shock
Free Fall
Humidity (Cycling)
Test Levels
0.01 m³/min @ 90 kPa (13 PSI) for 15 minutes
Velocity: 5 mm/s
Displacement: 1.5 mm
Acceleration: 2 m/s²
Frequency Range: 5 to 62 Hz, 62 to 200 Hz
3 Axes
Duration: 3x5 sweep
ASD: 0.04 m²/s³
12 to 12 dB/oct
Frequency Range: 5 to 10 Hz, 10 to 50, 50 to 100 Hz
3 axes, 30 min per axes
ASD: 1 m²/s³
-3 dB/oct
Frequency Range: 5 to 20 Hz, 20 to 200 Hz
3 axes, 30 min per axes
Spectrum: Half sine
Duration: 11 ms
Accelerator: 50 m/s²
100 shocks in each direction
Spectrum: Half sine
Duration: 6 ms
Accelerator: 180 m/s²
100 shocks in each direction
Height: 1 m (3.3 ft)
One fall on 3 faces, 3 edges and 4 corners
30 °C (86 °F) @ 90 to 100% for 2 cycles
40 °C (104 °F) @ 90 to 100% for 2 cycles
RUGGEDCOM WIN5237-IS
Installation Guide
Environmental Type Tests