Technical Datas; Hardware Features - Siemens 7XV5651-0 A00 Series Operating Instructions Manual

Table of Contents

Advertisement

3 Technical datas

3.1 Hardware features

Mechanical design
Housing
Dimensions
Weight
Degree of protection
Housing
Terminals
Auxiliary voltage U
Rated input voltage
- DC voltage
- AC voltage
Fuse internal
Class of protection (depends on
input voltage)
Power consumption
- DC voltage
- AC voltage
Alarm relay
1 Relay
Connector
Test voltage
Switching voltage (nominal value)
Switching capability
Switching current
Fault indicator
RS485-interface
Connector
Baudrate
Test voltage
12.10.2006
Plastic, EG90
see dimensional drawings
approx. 250g
according EN60529, IEC60529
H
24 V - 250 V DC ± 20 %
24 V - 230 V AC ± 20 % / 45-65 Hz
1,25 A slow blow (not changeable)
III
With U
3 W
2.5 W; 3.5 VA
MSR-Relay, 1 NC (open) contact,
potential free
2-pol. Phönix terminal
3,7 kV
250 V DC
20 W/VA
1 A permanent
LED green: 5 V o.k,
9-pol. SUB-D, socket or
2-pole Phoenix terminal
9600 - 115200 bauds
2 kV AC towards other connections
RS485-FO Converter 2-channel
IP 51 plasic
IP 20
= U
; typical value
H
HN
eff
Page 11 of 28