Thermostat Installation - USSC Ashley AP5660L Installation And Operating Manual

Table of Contents

Advertisement

Optional thermostats are available for use with your pellet stove. A thermostat can help you maintain a constant room
temperature. The thermostat option will require the installation of a millivolt type thermostat.
NOTE: Your thermostat should be installed by an authorized dealer or service person.
Installation of Remote Thermostat:
Disconnect Pellet Stove Room Heater unit from power supply.
Open right side panel to gain access to rear of control panel.
Strip insulation from thermostat wires and connect to the screw terminal on the rear of the control panel (see Figure 4).
If you have installed a remote thermostat for your pellet stove and wish to have the heater controlled by that thermostat,
depress the MODE button to engage T-STAT mode. The thermostat will control the heat output of the heater alternating
between the lowest heat level and the highest heat level that you have pre-selected.
The T-STAT mode provides the most even heat output, for better comfort, and to extend the life of the pellet fuel ignition
system. Additionally, the constant fl ame serves as a warning for people and pets to keep away from the heater while it is
in operation.

THERMOSTAT INSTALLATION

Connection Terminal for External Th ermostat
Left : GND
Middle: Th ermostat
Right: 5V power source
Figure 4