FAILURE TO CLEAN AND MAINTAIN THIS UNIT AS INDICATED MAY RESULT IN POOR PERFORMANCE
AND HAZARDOUS SITUATIONS. CLEAN THE HEATER FREQUENTLY AS ACCUMULATION OF SOOT,
CREOSOTE OR FLYASH MAY OCCUR. NEVER CLEAN THE UNIT WHEN HOT.
Burn Pot:
Note: Let the unit cool to room temperature before inspecting the burn pot. Inspect the burn pot regularly to check
that the holes have not become plugged. If necessary clean thoroughly. It is imperative that the burn pot be re-
installed the correct way or the unit will not light. The end of the burn pot with an igniter hole in it (see Figure 23)
must be installed facing the rear of the unit. This hole allows the igniter to heat up the pellets to the point of ignition.
Igniter Hole
Burn Pot
Removed
Ash Pan Door

MAINTENANCE

21
Figure 23