The appliance, when installed must be electrically
connected and grounded in accordance with local codes
or, in the absence of local codes, with the current CSA
C22.1 Canadian Electrical Code.
U.S. Installations, follow local codes and the National
Electrical Code, ANSI/NFPA No. 70.
Should this blower require servicing, the power supply
must be disconnected. For rewiring of any replacement
components, refer to Figures 24 and 25.
Operation
The fireplace insert is equipped with a factory installed blower
that includes a fan control switch, plus a rheostat (speed control).
The speed control knob is located in the lower compartment, at
the right side of the insert.
From a cold start, the temperature activated fan control switch
will normally take 5 to 20 minutes to heat up and energize the
blower.
Once the blower is energized, adjust the blower speed control as
desired, then replace the lower louver.
When the insert is shut off, it may take 30 to 40 minutes for the
heated unit to dissipate (cool down) enough for the blower to shut
off automatically.
NOTICE: The blower shut off times will vary on blower speed and
BTU input level setting control by adjustment of the HI/LO knob
located on the gas valve.
Blower removal instructions
Servicing or removal of the blower system must be performed by
a qualified service person.
If the blower assembly must be replaced, the following steps are
recommended for removal:
1.
Turn off gas and disconnect the electrical supply.
2.
Remove the barrier and glass door assembly.
3.
Remove the log set.
4.
Remove the front surround panel assembly.
5.
Remove the 5/16 x 2-1/2
Vent Slide plate assembly.
6.
Remove the insert from the fireplace cavity by pulling
forward on the insert, and at the same time, slide the vent
plate rearward until disengaged.
7.
As the insert is moved outward, the gas line may need to be
disconnected at the insert shut off valve. If so, make sure the
main gas line is shut off that supplies gas to the insert.
8.
Once the insert is pulled out, the blower assembly can be
removed by locating the six screws on the lower back of the
insert that retains the blower base plate.
9.
When the screws are removed, gently pull the blower
assembly outward.
10. Disconnect the two
¼-inch
11. Remove the four screws that retain the blower assembly to
the mounting plate, and set blower aside.
12. Install the replacement blower, and re-install into the insert
by reversing the above steps.
41380-0-0120

BLOWER INFORMATION

inch
center bolt that retains the
wire terminals from the motor.
BLOWER ASSEMBLY
PIEZO IGNITOR
MILLIVOLT VALVE
Figure 24
FAN
FAN CONTROL
SWITCH
WHITE
SPEED
CONTROL
Figure 25
THE FAN CONTROL SWITCH IS
CLIPPED BETWEEN THE BURNER
BASE AND VALVE BRACKET
REMOTE/OFF/ON SWITCH
FAN SPEED CONTROL
110 VOLT AC
JUNCTION BOX
BLACK
GROUND
Page 23