  • Page 1 G2270 Premium Mini Digital Thermostat works with with Wi-Fi and local API Owner’s Manual & Installation Instructions...
  • Page 2 Notice: Only peripherals complying with FCC limits may be attached to this equipment. Operation with noncompliant peripherals or peripherals not recommended by Goodman, is likely to result in interference to radio and TV reception. Changes or modifications to the product, not expressly approved by Goodman could void the user’s authority to operate the equipment.
  • Page 3 être choisis afin que la puissance isotrope rayonnée équivalente (PIRE) ne est pas plus de ce qui est nécessaire pour une communication réussie. We, Goodman, declare under our sole responsibility that the device to which this declaration relates: Complies with Part 15 of the FCC Rules. Operation is...
  • Page 4: Table Of Contents

    Turning on the Time Period Program ........29 Advanced Setup Table ............34 CAUTION IMPORTANT Follow Installation Instructions carefully. Disconnect Power to the Heater/Air Conditioner before removing the old thermostat and installing the new thermostat. G2270 © Copyright 2018, All Rights Reserved...
  • Page 5 Glossary of Terms Auto-Changeover: A mode in which the thermostat will turn on the heating or cooling based on room temperature demand. Cool Setpoint: The warmest temperature that the space should rise to before cooling is turned on (without regard to deadband). Deadband: The number of degrees the thermostat will wait, once a setpoint has been reached, before energizing heating or cooling.
  • Page 6: Installation Instructions

    Installation Instructions Remove and Replace the old thermostat To install the thermostat properly, please follow these step by step instructions. If you are unsure about any of these steps, call a qualified technician for assistance. • Installation tools: Small flat blade screwdriver, Phillips screwdriver, wire cutters and wire strippers.
  • Page 7: Wire Connections

    Installation Instructions Wire Connections If the terminal designations on your old thermostat do not match those on the new thermostat, refer to the chart below or the wiring diagrams that follow. Wire from the Install on the old thermostat Function new thermostat terminal marked connector marked...
  • Page 8: Thermostat Backplate

    Installation Instructions The Goodman Premium Mini Thermostat Backplate To remove the thermostat backplate: Gently separate the display from the base by pulling from the center. 24 VAC return 2nd stage compressor relay Fan relay 24 VAC common W1/O/B 1st stage heat circuit...
  • Page 9: Dip Switch Settings

    Installation Instructions Check Dip Switch Ensure which switch is correct for your system. Dip switches are located on the back of the thermostat. GAS/EL ELEC GAS/EL ELEC This switch (GAS or ELEC) controls how the thermostat will control the Fan (G) terminal in heating mode.
  • Page 10 Installation Instructions 1 Stage Heat, 1 stage Cool Dip Switch Settings Thermostat HVAC Equipment O or B...
  • Page 11 Installation Instructions 2 Stage Heat, 2 Stage Cool Dip Switch Settings Thermostat HVAC Equipment O or B...
  • Page 12 Installation Instructions Single Stage Heat Pump with AUX Heat Dip Switch Settings *Reversing valve choice, O or B, is dependant on the type of valve installed in the heat pump. Thermostat HVAC Equipment O or B...
  • Page 13 Installation Instructions Dual Stage Heat Pump with AUX Heat Dip Switch Settings *Reversing valve choice, O or B, is dependant on the type of valve installed in the heat pump. Thermostat Aux heat will turn on with second stage of heatpump heating HVAC Equipment...
  • Page 14 Installation Instructions Heat Only - with a 2-Wire Kit - ACC0436 Dip Switch Settings Input 120 VAC Thermostat HVAC Equipment BLACK BLACK O or B BROWN WHITE 24 VAC Isolation ORANGE Relay ACC-0437...
  • Page 15: Connect To Wifi

    Skyport account setup). 3. A 6-digit code obtained from the thermostat is successfully entered into a Skyport account. 4. Successfully download and install the Goodman Skyport app on your mobile device(s). Your thermostat operates on the 2.4 Ghz, Wi-Fi b/g/n band.
  • Page 16 Connect to Wi-Fi Overview Wi-Fi Setup The Goodman Configurator App is needed to configure the Wi-Fi Settings of this thermostat • Download the Goodman Configurator App from your mobile device’s App Store. ICON • Open the Goodman Configurator App - Choose the Premium Mini thermostat by sliding the thermostat pictures at the top of the apps’...
  • Page 17 Connect to Wi-Fi Overview Join a Thermostat to Skyport If the thermostat is connected to the local Wi-Fi access point but not yet joined to an existing Skyport account, you may join the thermostat to the account by doing the following: 1.
  • Page 18: Front Panel

    Front Panel 1 Backlit Display 2 Up/Warmer, Down/Cooler Buttons 3 Mode Button 4 Fan Button 5 Heat or Cool Indicator Heat = Red, Cool = Green...
  • Page 19: Display

    Display Mode Indicators Selects the operational mode of the equipment. HEAT - Indicates the heating mode. COOL - Indicates the cooling mode. AUTO - Indicates the system will automatically changeover between heat and cool modes as the temperature varies. OFF - Indicates heating and cooling are turned off.
  • Page 20 Display 5 Morning, Day, Evening & Night icons Indicates the day part of the time period program. 6 Setup icon Indicates the thermostat is in the setup mode. 7 Fan icon When only the Fan icon is displayed, the fan is always on.
  • Page 21: Basic Operation

    Basic Operation Selecting Your Desired Temperature (adjusting the setpoints) Auto-Changeover Mode Pressing the WARMER or COOLER buttons in Auto mode will adjust both the heat and cool setpoints simultaneously. To adjust the heat and cool setpoints individually, choose HEAT mode to adjust the heat setpoint, and COOL mode to adjust the cool setpoint, then return to AUTO mode.
  • Page 22: User Setup

    User Setup TO ENTER MENUS BUTTON PRESS Table for button Setup Steps MODE & FAN for 5 seconds presses that are Time Schedule MODE & Up for 2 seconds required for Emergency Heat Up & FAN for 2 seconds entering various Lockout Buttons MODE, Up &...
  • Page 23: Backlight Operation

    User Setup: Backlight Operation (Continued) Setup step 1 adjusts the clock. Use the Warmer/Up or Cooler/Down buttons to adjust the time. Press the MODE button to advance to step 2. Select the day of the week using the Warmer/Up or Cooler/Down buttons.
  • Page 24: Service Filter

    User Setup: Service Filter These setup steps allow the user to monitor FAN runtimes and program service alerts. Service alerts appear on the display. If the thermostat is joined to a Skyport account, then the user may be alerted by Skyport Cloud Services when to change the filter.
  • Page 25 User Setup: Setpoint Limits Setpoint Limits (Setup Steps 11-13) When this feature is set to ON, the Heat and Cool Setpoints may be restricted to preset levels in Setup Steps 12 and 13. Maximum Heat Setpoint (Setup Step 12) Minimum Cool Setpoint (Setup Step 13)
  • Page 26: Installer Setup

    Installer Setup Cycles Per Hour (Setup Step 14) The Cycles Per Hour setting may limit the number of times per hour your HVAC unit may energize. For example, at a setting of 6 cycles per hour the HVAC unit will only be allowed to energize once every 10 minutes.
  • Page 27 Installer Setup Deadband Settings (setup steps 17-20) The Deadband is the number of degrees or minutes that the thermostat waits before it initiates the stages of heating or cooling. 1st Stage Deadband (Setup Step 17) Specifies the temperature difference between the room temperature and the desired setpoint before the first stage of heating or cooling is allowed to turn on.
  • Page 28 Installer Setup Fan Off Delay in Seconds (setup step 21) This feature allows the user to increase the cooling or electric strip heating efficiency of the system. The thermostat may be programmed to continue running the fan after a call for cooling or electric strip heating has been satisfied.
  • Page 29 Installer Setup Dry Contact Operation Dry Contact Polarity (setup step 24) Open (Normally Open) - The dry contact is open until the connected device closes the circuit. ‘Idle’ ‘Active’ ‘Idle’ ‘Active’ Closed (Normally Closed) - The dry contact is closed until the connected device opens the circuit.
  • Page 30 Installer Setup Skyport Cloud Services (setup step 26) If set to ON, the thermostat may communicate and receive data from the Skyport Cloud Services. Local API (setup step 27) Turning on the local API allows 3rd party software to interface with the thermostat such as a home automation system.
  • Page 31 Installer Setup Locking/Unlocking the Keypad To prevent unauthorized use of the thermostat, the front panel buttons may be disabled. To disable, or ‘lock’ the keypad, press and hold the MODE button. While holding the MODE button, press the WARMER and COOLER buttons together, for two seconds. icon will appear on the display, then release the buttons.
  • Page 32: Programming A Daily Schedule

    Programming a Daily Schedule Programming a Daily Schedule To enter Time Period Programming screens, Press and hold MODE and UP until MODE the scrolling prompt appears. Select Day of Week to program - Press the WARMER or COOLER buttons to choose the day of the week.
  • Page 33 Programming a Daily Schedule Select Morning Mode - Press the WARMER or COOLER buttons to select the desired mode, which includes OFF. Press MODE to advance to the next step. Select Morning Start Time - Press the WARMER or COOLER buttons to adjust the time of day desired.
  • Page 34: About Advanced Features & Operation

    About Advanced Features & Operation Deadband Operation Controls up to two Heat and two Cool stages. The 1st Stage of heat or cool is turned on when: (A) The temperature spread from the setpoint is equal to or greater than: the setpoint plus the 1st stage deadband. This 1st stage dead- band is adjustable from 1-6 degrees and the default is two degrees.
  • Page 35 About Advanced Features & Operation Emergency Heat Only available if you have a Heat Pump installed. To initiate the Emergency Heat feature, press the FAN button. While holding the FAN button press the UP button for two seconds. The display will read ‘EM HEAT’ (Emergency Heat).
  • Page 36 About Advanced Features & Operation Calibration Under normal circumstances it will not be necessary to adjust the calibration of the temperature sensor. If calibration is required, please contact a trained HVAC technician to correctly perform the following procedure. MODE Place the thermostat in the OFF mode. Press and hold the MODE button.
  • Page 37 About Advanced Features & Operation Factory Defaults If, for any reason, you desire to return all the stored settings back to the factory default settings, follow the instructions below. WARNING: This will reset all Time Period and Advanced Programming to the default settings. Any information entered prior to this reset will be permanently lost.
  • Page 38 About Advanced Features & Operation (Continued) You now have the option of restoring the factory settings to just Wi-Fi (Wi-Fi), or just the thermostat (STAT), or both the thermostat and Wi-Fi (ALL). C. Select one of the above options using the Up or Down buttons.
  • Page 39: Advanced Setup Table

    Advanced Setup Table FD = Factory Default Setting Step# Description Pg# Range Set Clock 12A - 12A Set Day of Week Monday - Sunday Backlight On, Off, 6pm-6am Night Dimmer On/Off Night Dimmer Start Time 12A - 12A 8:00PM Night Dimmer Stop Time 12A - 12A 6:00AM Current Service Filter Runtime Hours...
  • Page 40 Warranty One-Year Warranty - This Product is warranted to be free from defects in material and workmanship. If it appears within one year from the date of original installation, whether or not actual use begins on that date, that the product does not meet this warranty, a new or remanufactured part, at the manufacturer’s sole option to replace any defective part, will be provided without charge for the part itself provided the defective part is returned to the distributor through a qualified servicing dealer.