Specifications; Troubleshooting - Toyotomi TAD-T40LW-R Instruction Manual

Table of Contents

Advertisement

Available languages

Available languages

4.
Clean the air intake grill (B1) and replace it.
5.
Store the unit.
The original shipping carton is the best place to store your unit.
If you do not have the original packing materials, cover the unit
with a large plastic bag and store in a cool dry place.
CAUTION
¡ ALWAYS store the unit in the vertical position.
¡ DO NOT put heavy objects on top of the unit.
7. TRANSPORTATION
Preferably keep the unit in the vertical position during transportation.
If this is not possible then lay it on its rear side, when at destination
put the unit back in the vertical position and wait at least ten (10)
minutes before using it. Before transporting/moving the unit make
sure the drain tank is empty.

8. TROUBLESHOOTING

SYMPTOM
CAUSE
Unit does
- Power cut.
not work.
- The plug has been
plugged improperly.
- The full-tank indicator
is ON. Tank is full.
- Current leaking or
pressing test button of
LCDI plug.
Unit sudden-
- The indoor tempera-
ly stops dur-
ture has reached the
ing in opera-
set temperature level.
tion.
- The preset time is up.
- The full-tank indicator
is ON. Tank is full.
Unit runs in-
- Malfunction.
termittently.
- Surrounding tempera-
ture is too high or too
low.
- Duct hose is blocked.
Unit func-
- Window or door is left
tions but the
open in the room.
room is not
- There is heat source in
cooled.
the room or too many
of people in it.
- Air intake grille is
clogged.
- Filter is too dirty.
- Temperature setting is
too high.
Condensed
- The tank is nearly full.
water is
spilled out
when moving
the unit.
BEFORE CALLING FOR SERVICE
The followings are not defects.
A hissing noise or hollow
e This sound is generated from the
sound :
e
A squeaking noise :
e Such odor as tobacco, cosmetics,
Odor :
The unit does not start nor
e
change operation mode im-
mediately :
SOLUTION
- Wait for power to be
supplied again.
- Plug in again.
- Remove the drain wa-
ter from the drain tank.
- Press reset button af-
ter solving the prob-
lem.
- Reset the temperature
level.
- Reset the timer.
- Remove the drain wa-
ter from the drain tank.
- Contact your dealer.
- Check the duct hose.
- Close all windows and
door.
- Move out any heat
source in the room.
- Clean the air intake
grille.
- Replace the filter.
- Lower the temperature
setting.
- Remove the drain plug
on the rear bottom of
the unit, drain off the
water then the unit will
be in operation auto-
matically.
refrigerant flowing within pipes.
This noise is generated from the
unit when it is expands or con-
tracts with temperature changes.
or foods may accumulate in the unit.
To prevent overloading the com-
pressor motor, the unit will be
stopped for more than 3 minutes.

9. SPECIFICATIONS

MODEL
COOLING CAPACITY
HEATING CAPACITY
DEHUMIDIFYING CAPACITY
POWER SOURCE
POWER CONSUMPTION
OPERATING CURRENT
AIR FLOW (MAX.)
OPERATING TEMP. RANGE
DIMENSIONS (WxHxD)
WEIGHT
COMPRESSOR
REFRIGERANT
NOTE: Cooling air capacity will vary according to temperature and
humidity of the room.
10.VENTING KIT ACCESSORIES
If the unit is to be used exclusively in one space, the cooling effi-
ciency will be enhanced by using the following venting kit acces-
sories.
DUCT SET (FLEXIBLE TUBE) (Fig. I)
2 pcs.
Max. 4 ft. (1.2 m)
WINDOW PANEL KIT "C" (Fig. J)
Window panel kit "C"
For sliding and double-hung windows
Max. 37 in. (94 cm)
Min. 28-1/4 in. (72 cm)
USING DUCT SET (Fig. I)
1. Extend one-side ends of the duct hose
(flexible tube) (I2) around 4 in. (100mm).
2. Insert both ends of duct hose (flexible
tube) (I2) into duct hose adapter nozzles
(I1) by twisting clockwise until it stops.
3. Fix one of the duct hose adapter nozzles onto the rear outlet of
the unit. This is completed by sliding the duct hose adapter
nozzle of the hose downwards over the outlet of the unit, which
will be assembled with the grooves on the connector of the unit.
(B2 or B7)
4. Extend the duct hose (I2) and close the window or door as far as
possible trapping the duct hose adapter nozzle (I1).
NOTE: Place the unit as close as possible to the window or door.
USING WINDOW PANEL KIT (Fig. J)
NOTE: Window installations are possible by the use of the duct set
and window panel kit.
In case of twin duct type, always use the window panel kit
"C".
1. Fix the duct hose grille (J3) to the window panel with four (4)
screws. Make sure that the panel is extended so that screws do
not go into sliding portion of panel.
3
ENGLISH
TAD-T40LW
14,000 BTU/H
11,000 BTU/H
0.48 gal/h (1.8 L/H)
Single Phase 115V, 60Hz
1200 W
(Cooling) 10.8 A
(Heating) 10.8 A
222 CFM (6.3 m
3
/m)
64˚F~100˚F (18˚C~38˚C)
19-11/16" x 33-5/8" x 15-3/4"
(500 x 854 x 400 mm)
77 Lbs. (35 kg)
ROTARY
R-410A
4 in.