Troubleshooting; Specifications - Toyotomi TAD-24E Operating Manual

Mobile air conditioner
Table of Contents

Advertisement

8. TROUBLESHOOTING

SYMPTOM
CAUSE
Unit
does
- Power cut.
not work.
- The plug has been
plugged improperly.
- The full-tank indicator
is ON. Tank is full.
Unit sudden-
- The indoor tempera-
ly stops dur-
ture has reached the
ing in opera-
set temperature level.
tion.
- The preset time is up.
- The full-tank indicator
is ON. Tank is full.
Unit runs in-
- Malfunction
termittently.
- Surrounding tempera-
ture is too high or too
low.
- Exhaust duct hose is
blocked.
Unit
func-
- Window or door is left
tions but the
open in the room.
room is not
- There is heat source in
cooled.
the room or too many
of people in it.
- Air intake grille is
clogged.
- Filter is too dirty.
- Temperature setting is
too high.
C o n d e n s e d
- The tank is nearly full.
water
is
spilled out
when moving
the unit.
BEFORE CALLING FOR SERICE
The following are not defects.
A hissing noise or hollow
e
sound :
e
A squeaking noise :
e
Odor :
The unit does not start nor
change operation mode im-
e
mediately :
SOLUTION
- Wait for power to be
supplied again.
- Plug in again.
- Remove the drain wa-
ter from the drain
tank.
- Reset the temperature
level.
- Reset the timer.
- Remove the drain wa-
ter from the drain
tank.
- Contact your dealer.
- Check the duct hose.
- Close all windows and
door.
- Move out any heat
source in the room.
- Clean the air intake
grille.
- Replace the filter.
- Lower the tempera-
ture setting.
- Remove the drain plug
on the rear bottom of
the unit, drain off the
water then the unit will
be in operation auto-
matically.
This sound is generated from the
refrigerant flowing within pipes.
This noise is generated from the
unit when it is expands or con-
tracts with temperature changes.
Such odor as tobacco, cosmetics,
or foods may accumulate in the
unit.
To prevent overloading the com-
pressor motor, the unit will be
stopped for more than 3 minutes.

9. SPECIFICATIONS

MODEL
COOLING CAPACITY
EE Class / EER*
DEHUMIDIFYING CAPACITY
POWER SOURCE
POWER CONSUMPTION
OPERATING CURRENT
AIR FLOW (MAX.)
FOR ROOMS UP TO
OPERATING TEMP. RANGE
SOUND POWER LEVEL
UNIT PROTECTION
FUSE RATING
DIMENSIONS (WxHxD)
WEIGHT
COMPRESSOR
REFRIGERANT
NOTE: Cooling air capacity will vary according to temperature and
humidity of the room.
CONTAINS FLUORINATED GREENHOUSE GASES COVERED BY
THE KYOTO PROTOCOL.
HERMETICALLY SEALED SYSTEM
10. VENTING KIT ACCESSORIES
If the unit is to be used exclusively in one space, the cooling effi-
ciency will be enhanced by using the following venting kit acces-
sories.
EXHAUST DUCT SET (FLEXIBLE TUBE) (Fig. H)
USING EXHAUST DUCT SET (Fig. H)
1.
Insert both ends of exhaust duct hose (flexible tube) (H3) into
exhaust duct hose adapter nozzle (H1) by turning it counter
clockwise onto the tube and fix one of the exhaust dust hose
adapter nozzle (H1) into exhaust outlet (B2) by turning it clock-
wise until it locks.
2.
Extend the exhaust duct hose (H3) and close the window or
door as far as possible trapping the exhaust nozzle (H2)
NOTE:
Place the unit as close as possible to the window or
door. (H4, H5, H6)
3
ENGLISH
TAD-24E
2.33 kW (8,000BTU)
A / 2.61
1.4 L/H
Single Phase 220~240 V, 50 Hz
890 W
3.9 A
220 m
3
/h
48 m
3
18 ˚C ~ 35 ˚C
65 dB
IP X0
T3.15A / 250V
350 x 325 x 720 mm
21 kg
ROTARY
R-410A / 380g
Max.1.2m