Complete Installation And Check Operation; Range Hood Use - KitchenAid KVWC906KSS Installation Instructions Use And Care Manual

36" and 48" (91.4 cm and 121.9 cm) commercial style wall-mount
Hide thumbs Also See for KVWC906KSS:
Table of Contents

Advertisement

Available languages

Available languages

A
B
C
D
A. White wires
B. Black wires
C. UL listed wire connectors
D. Green, bare or yellow/green wires
E. Home power supply
F. UL listed or CSA approved 1/2" (1.3 cm) strain relief
3. Use UL listed wire connectors and connect black wires (B)
together.
4. Use UL listed wire connectors and connect white wires (A)
together.
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire
in terminal box.
Failure to do so can result in death or electrical shock.
NOTE: When using an in-line blower motor system, the green (or
green/yellow) ground wire in the conduit from the In-line blower
motor system is to be connected with the green (or bare) wire of
the home power supply cable and with the green/yellow wire (D)
in the terminal box.
5. Connect green (or bare) ground wire from home power
supply to the green/yellow ground wire (D) in terminal box
using UL listed wire connectors.
6. Install terminal box cover.
7. Check that all light bulbs are secure in their sockets.
8. Reconnect power.
E
1. Install grease fi lters. See "Range Hood Care" section.
2. Check operation of the range hood blower and lights. See
F
3. If range hood does not operate, check to see whether a
NOTE: To get the most effi cient use from your new range hood,
read the "Range Hood Use" section.
The range hood is designed to remove smoke, cooking vapors
and odors from the cooktop area. For best results, start the
hood before cooking and allow it to operate several minutes
after the cooking is complete to clear all smoke and odors from
the kitchen.
Complete Installation and Check
Operation
"Range Hood Use" section.
B
C
A. Control switches
B. LED light
C. Grease fi lter handles
D. Grease fi lter
circuit breaker has tripped or a household fuse has blown.
Disconnect power supply and check that the wiring is
correct.

RANGE HOOD USE

A
A
A. Fan speed control
B. Fan Boost level
C. Light intensity control
A
D
B
C
13

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kvwc906kss0Kvwc908kss0

Table of Contents