Roof Exhaust With Traditional Fireplace - Royal DORA AIR Installation And Maintenance Manual

Table of Contents

Advertisement

Available languages

Available languages

ONLY FOR DORA
On the first vertical tee, at the flue gas outlet of
the appliance, a pipe must be connected at the
bottom to drain any condensate that may form
in the chimney (Fig. 22).
ONLY FOR GRAZIA
As an additional safety measure, a threaded cou-
pling with "R" closing cap is provided in order to
connect a condensate drain pipe (Fig. 23).
004778391 - 23/09/2021
6.6 Roof exhaust with traditional
The chimney for the evacuation of flue gases
must be made by qualified personnel in compli-
ance with standards UNI 10683- EN 1856-1-2- EN
1857-EN 1443- EN 13384-1-3- EN 12391-1 both in
terms of the dimensions and the materials used
in its construction.
The flue gases can be evacuated through a tra-
ditional chimney (Fig. 24 - Fig. 25-) provided the
good condition and proper maintenance of the
chimney has been verified. In the case of an old
chimney, it is advisable to renew it using ducting.
The flue gas exhaust must be on the roof.
Fig. 22
DORA
R
Fig. 23
1) Wind-proof cowl
2) Seal
3) Inspect
ITALIANO
ENGLISH
fireplace