Ptc And Olp - Kenmore 795.75192401 Service Manual

Hide thumbs Also See for 795.75192401:
Table of Contents

Advertisement

https://appliancetechmanuals.com

6-2 PTC AND OLP

Normal operation of
Compressor is
impossible or poor.
Separate PTC-Starter
from Compressor and
measure resistance
between No. 5 and 6
of PTC-Starter with a
Tester.
(Figure 20)
Shows continuity
Separate OLP from
Compressor and check
resistance value
between two terminals
Open
of OLP with a Tester.
(Figure 21)
Figure 20
- 13 -
Observation value is
115V/60Hz : 6.8Ω±30%
The resistance value
is 0Ω (short) or
∞ (open).
Check another
electric component.
Replace OLP.
Figure 21
Replace PTC-
Starter.