Grizzly G0508 Owner's Manual page 27

10 hp industrial dust collector
Hide thumbs Also See for G0508:
Table of Contents

Advertisement

Always guard against
static electrical build up
by grounding all dust
collection lines.
Ensure that the entire system is grounded. If using
plastic blast gates to direct air flow, the grounding
wire must be jumped (Figure 32) around the
blast gate without interruption to the grounding
system.
Figure 32. Ground jumper wire when using
plastic blast gates and metal duct.
-24-
We also recommend wrapping the outside of all
plastic ducts with bare copper wire to ground the
outside of the system against static electrical build
up. Wire connections at Y's and T's should be
made with wire nuts.
Attach the bare ground wire to each stationary
woodworking machine and attach to the dust
collector frame with a ground screw as shown in
Figure 33. Ensure that each machine is continu-
ously grounded to the grounding terminal in your
electric service panel.
G0508 10 HP Industrial Dust Collector