Whirlpool HYBRIDCARE YWHD560CHW0 Installation Instructions Manual page 10

Heat pump dryer
Table of Contents

Advertisement

1.
Prepare to connect neutral ground
wire and neutral wire
E
Remove center terminal block screw (B). Remove neutral
ground wire (E) from green external ground conductor screw (A).
2.
Connect neutral ground wire and
neutral wire
Connect neutral ground wire (E) and neutral wire (white or
center) (C) of power supply cord under center terminal block
screw (B). Tighten screw.
3.
Connect ground wire
A
F
Connect ground wire (F) (green or bare) of power supply cord
under green external ground conductor screw (A). Tighten
screw.
10
4.
Connect remaining wires
B
A
Connect remaining wires under outer terminal block screws.
Tighten screws. Finally, reinsert tab of terminal block cover
into slot of dryer rear panel. Secure cover with hold-down
screw. Now, go to "Connect Outlet Hose."
3-Wire Power Supply Cord Connection
Use where local codes permit connecting cabinet-ground
conductor to neutral wire.
B
E
C
3-wire receptacle
(NEMA type 10-30R)
Spade terminals with
upturned ends
1.
Remove center screw
Remove center terminal block screw (B).
3 prong plug
Ring terminals
B

Advertisement

Table of Contents
loading