Amprobe 3434877 User Manual page 12

Cat iv industrial true rms clamp meters
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
Peak Hold:
Ranges:
66.00V, 660.0V, 750V
** Frequency: 10% to 100% of voltage range
AC coupled TRMS: 5% to 100% of range
Crest factor: ≤ 3
Input impedance: 660 mV: >100 MΩ; 6.6 V:10 MΩ; 66 V to 750 V: 9.1 MΩ
Overload protection: 1000 VDC or 750 VAC rms
AC CURRENT TRUE RMS
Ranges:
66.00A*
66.00A*
660.0A
660.0A
1000 A
1000 A
Frequency**
Peak Hold:
Ranges:
66.00A*, 660.0A,1000A
* ACD-3300 IND only
** Frequency: 10% to 100% of current range
AC coupled TRMS: 5% to 100% of range
Crest factor: ≤ 3
Overload protection: 1000A AC
DC CURRENT (ACDC-3400 IND only)
Range
660.0A
1000A
Overload protection: 1000A DC
frequency
50 to 500 Hz
frequency
50 to 60 Hz
61 to 400 Hz
50 to 60 Hz
61 to 400 Hz
50 to 60 Hz
61 to 400 Hz
50 to 1kHz
frequency
50 to 400 Hz
Accuracy
± (2.0% rdg + 5 dgts)
± (3.0% rdg + 5 dgts)
11
Accuracy
± (3.0% rdg + 200 dgts)
Accuracy
± (2.0% rdg + 10 dgts)
± (3.0% rdg + 10 dgts)
± (2.0% rdg + 10 dgts)
± (3.0% rdg + 10 dgts)
± (2.5% rdg + 10 dgts)
± (3.5% rdg + 10 dgts)
± (0.1% rdg + 5 dgts)
Accuracy
± (3.0% rdg + 200 dgts)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Acdc-3400 indAcd-3300 ind

Table of Contents