THEORY OF
OPERATION
The air pump forces air
The Fuel System:
through the air line. The air is then pushed
through the burner head nozzle. This air
causes fuel to lift from the tank. A fine mist
of fuel is sprayed into the combustion cham-
ber.
The Air System:
The motor turns the fan.
The fan pushes air into and around the
combustion chamber. This air is heated and
provides a stream of clean, hot air.
The ignition control
The Ignition System:
assembly provides power to the ignitor.
This ignites the fuel/air mixture in the com-
bustion chamber.
The Flame-Out Control System:
tem causes the heater to shut down if the
flame goes out.
Combustion Chamber
Clean
Heated
Air Out
Nozzle
Fuel
Tank
Air For Fuel System
Figure 4 - Cross Section Operational View
107689
OPERATION
WARNING: Review and un-
derstand the warnings in the
Safety Information section, page
2. They are needed to safely op-
erate this heater. Follow all local
codes when using this heater.
TO START HEATER
1. Follow all ventilation and safety infor-
mation.
2. Fill fuel tank with kerosene or No. 1
fuel oil.
3. Attach fuel cap.
4. Plug power cord of heater into standard
230 volt/50 hertz, grounded (earthed)
This sys-
outlet. Use an extension cord if needed.
Use only a three-prong, grounded
(earthed) extension cord.
Motor
Ignitor
Fan
Fuel
Air Line
Filter
To Burner
Air For Combustion
And Heating
OWNER'S MANUAL
EXTENSION CORD WIRE
SIZE REQUIREMENTS
Up to 30.5 meters (100 feet) long, use 1.0
mm
30.6 to 61 meters (101 to 200 feet) long, use
1.5 mm
Push ON/OFF switch to ON (|) position and
heater should start in 5 seconds. If heater
does not start, see Troubleshooting (page 7).
TO STOP HEATER
Push ON/OFF switch to OFF (O) position.
TO RESET HEATER
1.
2.
Air Pump
Air Intake
Filter
Cool
Air
In
Air
Figure 5 - ON/OFF Switch, REMSA35H and
Output
REMSA70H Models
Filter
Ignition Control
Assembly
Fuel
Figure 6 - ON/OFF Switch, REMSA100H
and REMSA150H Models
5
2
(16 AWG) conductor
2
(14 AWG) conductor
Push ON/OFF switch to OFF (O) posi-
tion and wait 10 seconds (2 minutes if
heater has been running).
Repeat steps under To Start Heater.
ON/OFF Switch
with Light
|
O
ON/OFF Switch
|
with Light
O