Field settings table

First
Second
code
code
Setting name
0
Remote control setup
00
User permission level
01
Room temperature compensation value
02
Not applicable. Do not change the default value.
03
Status: space heating schedule timer mode
1
Automatic storage timing for domestic water heating
00
Status: night time storage
01
Night time storage start time
02
Status: day time storage
03
Day time storage start time
2
Automatic setback function
00
Status: setback operation
01
Setback operation start time
02
Setback operation stop time
3
Weather dependent set point
00
Low ambient temperature (Lo_A)
01
High ambient temperature (Hi_A)
02
Set point at low ambient temperature (Lo_Ti)
03
Set point at high ambient temperature (Hi_Ti)
4
Disinfection function
00
Status: disinfection operation
01
Disinfection operation day selection
02
Disinfection operation start time
5
Automatic setback and disinfection set point
00
Set point: disinfection operation temperature
01
Disinfection operation time duration
02
Leaving water setback temperature
03
Room setback temperature
6
Option setup
00
Domestic hot water tank installed
01
Optional room thermostat installed
02
Not applicable. Do not change the default value.
03
Not applicable. Do not change the default value.
04
Benefit kWh power supply mode
7
Option setup
00
Optional bottom plate heater installed
01
Not applicable. Do not change the default value.
02
Multiple set point pattern
03
Multiple set point 1
04
Multiple set point 2
8
Option setup
00
Remote controller temperature control
01
Status: automatic restart function
02
Emergency mode
03
Status: low noise level
04
Status: freeze up prevention
EKHBRD011~016AAV1+Y1
Indoor unit for air to water heat pump system
4PW54465-1C
Installer setting at variance with default value
Date
Value
Date
Default
Value
value
Range
2
2~3
0
–5~5
1 (ON)
0/1
1 (ON)
0/1
1 (ON)
0/1
1:00
0:00~23:00
0 (OFF)
0/1
15:00
0:00~23:00
1 (ON)
0/1
23:00
0:00~23:00
5:00
0:00~23:00
–10
–20~5
15
10~20
70
25~80
45
25~80
1 (ON)
0/1
Fri
Mon~Sun
23:00
0:00~23:00
70
60~75
10
5~60
5
0~10
18
17~23
0 (OFF)
0/1
0 (OFF)
0/1
0 (OFF)
0/1
0 (OFF)
0/1
0
0/2
0 (OFF)
0/1
0 (OFF)
0/1
0 (A)
0/1
0 (OFF)
0/1
0 (OFF)
0/1
1 (ON)
0/1
1 (ON)
0/1
0 (OFF)
0/1
1
1~3
0
0~2
Step
Unit
1
0.5
°C
1:00
hour
1:00
hour
1:00
hour
1:00
hour
1
°C
1
°C
1
°C
1
°C
1:00
hour
5
°C
5
min
1
°C
1
°C
1
1
1