Engineering Data
Load Current vs. Ambient Temperature
Vertical Mounting
Panel
Ground
G3PA-210B(L)-VD, G3PA-220B(L)-VD
G3PA-220B(L)-VD
25
G3PA-210B(L)-VD
15
Ambient temperature (°C)
G3PA-220B-VD
For single mounting, the ambient temperature is 80°C. The rated current is 5 A.
For close mounting of two or three SSRs, limit the load current to 90% or less.
G3PA-420B-VD, G3PA-420B-VD-2
Ambient temperature (°C)
G3PA-420B-VD
For single mounting, the ambient temperature is 80°C. The rated current is 5 A.
For close mounting of two or three SSRs, limit the load current to 80% or less.
G3PA-240B(L)-VD
Ambient temperature (°C)
G3PA-430B-VD, G3PA-430B-VD-2
Ambient temperature (°C)
G3PA-260B(L)-VD
80
60
40
25
20
-30
-20
0
20
40
60
Ambient temperature (°C)
G3PA-450B-VD-2
Ambient temperature (°C)
G3PA
80
100
8