Warning: To reduce the
risk of personal injury,
do not drop the lamp
module or touch the
lamp bulb. The bulb
may shatter and cause
injury if it is dropped.
Do not break the glass
on the lamp module.
Keep finger prints off
the glass surface on the
lamp module. Leaving
finger prints on the
glass surface might
cause an unwanted
shadow and poor
picture quality.
Be sure to tighten the
screws after replacing
the lamp module.
Lamp Replacing Procedure:
1. Switch off the power to the projector by pressing the POWER OFF button on the
remote control or the
2. Allow the projector to cool down at least 60 minutes.
3. Disconnect the power cord.
4. Use a screwdriver to loosen the screw on the lamp cover. 
5. Slide and remove the cover. 
6. Loosen the screw on the lamp module. 
7. Lift the handle. x
8. Pinch the arrow marked positions on the connector housing and pull the housing
upward for removing the connector. y
9. Pull out the lamp module. z
10. Install the new lamp module by reversing the previous steps.
11. After replacing the lamp, turn on the power, and select the [MENU] button ->
OPTIONS |LAMP SETTINGS -> CLEAR LAMP HOURS to reset the lamp usage
hours. Please see page 73.
3
button on the control panel.
Appendices
2
4
5
6
1
85