Notice
2. Detach and attach the upper case.
Follow the procedure below to detach and attach the upper case.
When disassembling
a. Remove the Lamp door.
The lamp door must be removed before the upper case when disassembling the machine. If the upper
case is detached with the lamp door installed, the MAIN board might be damaged.
b. Remove 7screws on the bottom and 2 screws on the rear to detach the upper case.
2 screws
b'. Tighten screws in order of 1, 2, 3, 4, 5, 6 and 7 as shown in the diagram when assembling.
All manuals and user guides at all-guides.com
CPX2(M1-20WL)
CAUTION
6
7
52
Lamp door
Loosen this screw
5
4
7 screws
3
2
1