LG APUQ55GT3E0 Installation Manual page 8

Floor standing
Table of Contents

Advertisement

INSTALLATION OF OUTDOOR UNIT
8
Piping length and the elevation
Floor Standing Air conditioner
MODEL
Gas
APUQ55GT3E0
Ø19.05(3/4) Ø 9.52(3/8)
APUQ55GT3M0
APUQ55LT3E0
APUQ55LT3M0
APUQ55GT3A0
APUQ50LT3E0
APUW55GT3E0
Ø19.05(3/4) Ø 9.52(3/8)
APUW55GT3M0
APUW55LT3E0
APUW55LT3M0
APUW50GT3E0
APUW50LT3E0
If installed tube is shorter than 5 m, additional charging is not necessary.
Additional Refrigerant = (A -5) x Additional refrigerant (g)
Indoor unit
B
CAUTION
!
• Do not use the pipe less than 5 m. Otherwise, it may cause damage of compressor and to
form dewdrop on the indoor unit. Also, it may cause to decrease capacity.
• Capacity is based on the length of 5 m and maximum allowance length is on the basis of
reliability.
• Improper refrigerant charge may result in abnormal cycle.
Pipe Size
Length A (m)
Liquid
Standard
5
5
A
Outdoor unit
Elevation B (m)
Max.
Standard
Max.
30
-
20
30
-
20
Outdoor unit
A
Indoor unit
B
Additional Refrigerant
(g/m)
30
40