Airflow
Air is not blown out when starting the HEATING operation.
(1.5 seconds ON, 0.5 seconds OFF)
Air is not blown out for 5 to 15 minutes or cool air is
blown out for a moment at HEATING operation.
(1.5 seconds ON, 0.5 seconds OFF)
Air is not blown out when starting the DRY operation.
Noise
You hear a slight gurgling sound.
You hear a slight cracking sound.
You hear a hissing or clicking sound.
Whistling noise is heard from the outdoor unit.
Sometimes a "Shooooo" sound might come for a short
time from the unit that is turned off.
Others
The unit does not restart immediately after you have
stopped it.
Some steam releases during COOL operation.
There is a slight smell.
After a power cut, the unit does not restart even if power
has been restored.
Remote control signals are not received.
Moisture may form on the air outlet grills.
Fan will not stop immediately after unit operation is
stopped.
RUN light stays on even though operation was stopped.
Airflow has stopped to prevent blowing out of cold air until the
indoor heat exchanger has warmed up. (2 to 5 minutes)
RUN light blinks slowly
When outdoor temperature is low and humidity is high, the
unit sometimes performs defrosting automatically. Please
wait. During defrosting, water or steam may release from the
RUN light blinks slowly
outdoor unit.
The indoor fan may stop to prevent re-evaporation of
dehumidified moisture and to save energy.
(RUN light is on)
This is caused by refrigerant moving within the unit.
This is caused by heat expansion or contraction.
This is caused by the operation of the refrigerant control
valves or electric components.
This means that the rotation speed of the compressor is
increasing or decreasing.
This is the sound when operation of another indoor unit is
stopped.
Restart is blocked for 3 minutes after you have stopped the
operation to protect the unit.
(RUN light is on)
The 3 minutes protection timer in the microcomputer
automatically starts it up again.
This may occur if the room's temperature and humidity are
very high. It disappears as soon as the temperature and
humidity decrease.
Close all windows and doors to prevent outside humidity from
entering.
Air blown out during operation may smell. This is caused by
tobacco or cosmetics adhering to the unit.
If the auto restart function is not set, the unit will not restart
automatically. Use the remote control to start the operation
again.
Remote control signals may not be received if the signal
receiver on the air-conditioner is exposed to direct sunlight or
other bright light.
If so, block the sunlight or reduce the other light.
If the unit is operated for a long time in high humidity, moisture
may form on the air outlet grills and start dripping.
Indoor fan
Outdoor fan : Fan will not stop about a 1 minute period in
The RUN light illuminates during SELF CLEAN operation.
Run light will turn off when SELF CLEAN operation ends.
EN-30
: Fan will not stop after 2 hours if set to SELF
CLEAN operation.
order to protect the unit.