Kenwood KDC-X617 Service Manual page 6

Hide thumbs Also See for KDC-X617:
Table of Contents

Advertisement

KDC-X617,6090R/RY,7018
MICROCOMPUTER'S TERMINAL DESCRIPTION
Pin No.
Pin Name
39
CLKOUT
40
NC
41
NC
42
TYPE0
43
TYPE1
44
TYPE2
45
TYPE3
46
IC2TYPE0
47
IC2TYPE1
48
NC
49
NC
50
NC
51
NC
52
ILL-ON
53
M-MUTE L
54
M-MUTE R
55
BVDD
56
BVSS
57
M-RST
58
M-STOP
59
NC
60
LO/EJ
61
MOSW
62
NC
63
CD-SW3
64
NC
65
L-CE
66
NC
67
NC
68
NC
69
NC
70
AVCONT
71
AVDD
72
AVSS
73
AVREF
74
PHONE
75
NC(GND)
76
NC(GND)
77
SRT-SW2
78
SRT-SW1
79
NOISE
80
S-METER
81
R-DATA
6
I/O
Description
O
Internal system clock output
O
O
I
Destination type input terminal 0
I
Destination type input terminal 1
I
Destination type input terminal 2
I
Destination type input terminal 3
I
IC2 setting terminal
I
IC2 setting terminal
O
O
O
O
O
Illumination AVR on/off control output
I
Mute request (Lch) from CD MECHA. MI-COM. "Lo": Mute request
I
Mute request (Rch) from CD MECHA. MI-COM. "Lo": Mute request
-
Power supply connection terminal
-
Ground connection terminal
O
Reset output to CD MECHA. MI-COM.
O
Stop request to CD MECHA. MI-COM.
O
I/O CD MECHA. loading/Eject switching output "Lo": Loading, "Hi": Eject, "Hi-Z": Stop or Break
O
CD mechanism loading motor control output "Hi": CD loading/ eject action or Break, "Lo": other
O
I
Down & limit switch detection input
O
I/O CE output to LCD driver
O
O
O
O
O
A/D converter reference voltage control output
-
A/D converter power supply connection terminal Connected to BU 5V lines.
-
A/D, D/A converter ground connection terminal Connected to GND lines.
I
A/D converter reference voltage input terminal
I
PHONE detection input
I
I
I
SRT position detection input
I
SRT position detection input
I
FM noise detection input
I
S-meter input from F/E
I
Data input from the RDS decoder IC
Processing Operation
Not used (N.C.)
Not used (N.C.)
Not used (N.C.)
"Lo": Initial value
"Lo": Initial value
Not used(N.C.)
Not used(N.C.)
Not used(N.C.)
Not used(N.C.)
"Hi": POWER ON mode except panel detached
or panel mask position
Connected to BU 5V lines.
Connected to GND lines.
"Lo": Reset
"Lo": Stop mode, "Hi": Operation mode
Not used(N.C.)
Not used(N.C.)
"Hi": Chucking, "Lo": Pickup most inner position
Not used(N.C.)
Not used(N.C.)
Not used(N.C.)
Not used(N.C.)
Not used(N.C.)
"Hi": Active, Connected to AVREF terminal.
1V or less: TEL MUTE, 2.5V or greater: NAVI MUTE
Not used(pull down to GND lines)
Not used(pull down to GND lines)
Panel: (SW1, SW2)=(Hi, Hi)
Slide: (SW1, SW2)=(Hi, Lo)
Mask : (SW1, SW2)=(Lo, Lo)
Except RDS model: Not used (pull down to GND lines)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kdc-6090rKdc-6090ryKdc-7018

Table of Contents