KDC-X617,6090R/RY,7018
Ref.No.
Component Name
Q21
2SB1184
Q22
2SC4081 or 2SD1819A
Q25
DTA123JK or KRA105S
Q26
DTC144EUA or UN5213
Q27
DTC114YUA or UN5214
Q32
2SB1277(Q,R)
Q29
DTA124EUA or KRA303
Q30
2SA1576A or 2SB1218A
Q28
DTC114YUA or UN5214
Q31
2SB1277(Q,R)
Q33
2SC4081 or 2SD1819A
Q34
2SC4081 or 2SD1819A
Q42
DTC124EUA or UN5212
Q43
2SC4081 or 2SD1819A
Q45
DTC124EUA or UN5212
Q47
2SB1277(Q,R)
Q46
DTC124EUA or UN5212
Q48
2SB1277(Q,R)
Q51
DTC144EUA or UN5213
Q52
2SC4081 or 2SD1819A
Q55
2SA1576A or 2SB1218A
Q56
DTC124EUA or UN5212
G
CD PLAYER UNIT (X32-5030-00)
Ref.No.
Component Name
IC1
AN22000AA
IC2
MN662773KF1
IC4
BA5917AFP
IC5
TA78L05AFP
IC6
NJM4565MD
Q1
MCH6101
Q2
DTC124EUA
Q3
2SA1362 (Y)
Q4
2SA1362 (Y)
Q5
DTC124EUA
4
COMPONENTS DESCRIPTION
Application/Function
ILL +B AVR
EXT. AMP CON. SW
Small lamp detection SW
P-CON SW
P-CON. protection inhibit SW
P-CON. protection SW
ANT-CON. SW
BU detection SW
ACC detection SW
E. VOL mute SW
Noise buffer
FM +B SW
AM +B SW
IFC buffer
Composite signal output buffer
PAN 5V SW
Application/Function
RF amplifier
CD signal processor bult-in MI-COM.
4CH BTL driver
5V AVR
OP Amp.
APC
P ON SW
A.8V SW
D.5V SW
MOTOR SW
Operation/Condition/Compatibility
While Q22's base goes "Hi", AVR outputs +10.5V.
Works during POWER ON mode with a panel attached
to the set.
When a base goes "Lo", Q25 is turned on.
When vehicle small lamps turn on, Q26 is turned on .
When Q27's base goes "Hi", Q32 is turned on .
Works during POWER ON mode.
Prevents Q30 tuning ON during start-up after power ON.
Protect Q32 by turning ON when P-CON output is grounded.
When Q28's base goes "Hi", Q31 is turned on.
Works during TUNER mode.
While BACKUP is applied, a base goes "Hi",
and Q33 is turned on. When momentary power down
has detected, a base goes "Lo", and Q33 is turned off.
While ACC is applied, a base goes "Hi", and Q34 is turned on.
When BU detection SW or MI-COM.'s mute is working,
a base goes "Hi", and Q42 is turned on.
When Q45's base goes "Hi", Q47 is turned on .
Works during FM reception mode.
When Q46's base goes "Hi", Q48 is turned on .
Works during AM reception mode.
Waveform shaping
While a panel is attached to the set, Q56's base goes "Hi",
and Q55 is turned on.
Operation/Condition/Compatibility
Generation of RF signal based on the signals from the
APC circuit and pickup, and generation of servo error
(focusing error and tracking error)signals.
Detection of dropout, anti-shock, track crossing and
off-track conditions, Gain control function building in.
Focusing coil, tracking coil, spindle motor and sled
motor driver
AVR outputs +5V for D/A converter analogue part.
Low pass filter
LD power control
When CD source is selected, Q2's base goes "Hi",
Q3 and Q4 are turned on.
A8V ON/OFF control. When a base goes "Lo", Q3 is turnde on.
D5V ON/OFF control. When a base goes "Lo", Q4 is turnde on.
When CD loading or eject operation is activating,
Q5's base goes "Hi", Q4 is turned on.

Advertisement