If an accessory electric heater is installed, low voltage leads from
heater must be connected to factory supplied control leads from
Indoor Fan Board P4 connector.
NOTE: If the unit 24V wires do not have a matching receptacle,
cut the 24V wires from the electric heater plug, strip the ends, and
wire nut together to match the schematic connections. If the electric
heater 24V wires do not have a matching plug, cut the 24V wires
from the unit receptacle, strip the ends, and wire nut together to
match the schematic connections.
Factory wires are provided for electric heat staging W1 and W2
(W2 and W3 on IFB). If room thermostat has only one stage of
UNIT SIZE
NOMINAL CAPACITY (ton)
SHIPPING WEIGHT lb.
SHIPPING WEIGHT (kg)
COMPRESSORS
Quantity
REFRIGERANT (R --- 410A)
Quantity lb
Quantity (kg)
REFRIGERANT METERING DEVICE
ORIFICE
ID (in.)
ID (mm)
OUTDOOR COIL
Rows...Fins/in.
Face Area (sq ft)
OUTDOOR FAN
Nominal Cfm
Diameter in.
Diameter (mm)
Motor Hp (Rpm)
INDOOR COIL
Rows...Fins/in.
Face Area (sq ft)
INDOOR BLOWER
Nominal Low Stage Cooling Airflow (Cfm)
Nominal High Stage Cooling Airflow (Cfm)
Size in.
Size (mm.)
Motor HP (RPM)
HIGH --- PRESSURE SWITCH
(psig) Cut--- out Reset (Auto)
LOW --- PRESSURE SWITCH
(psig) cut--- out Reset (auto)
RETURN--- AIR FILTERS†}
Throwaway Size in.
Throwaway Size (mm)
{ Required filter sizes shown are based on the larger of the AHRI (Air Conditioning Heating and Refrigeration Institute) rated cooling airflow or the heating air-
flow velocity of 300 ft/minute for throwaway type or 450 ft/minute for high ---capacity type. Air filter pressure drop for non ---standard filters must not exceed 0.08
in. W.C.
} If using accessory filter rack refer to the filter rack installation instructions for correct filter sizes and quantity.
SIZE
24
Cfm
850
10
Table 1 – Physical Data
24
30
2
2 ---1/2
393
347
157
178
8.2
11.2
3.7
5.1
.032 (2)
.035 (1)
0.81 (2)
.89 (1)
1...21
2...21
18.8
18.8
2100
2500
24
24
609.6
609.6
1/12 (800)
1/8 (810)
3...17
3...17
3.7
3.7
675
675
775
775
855
1000
10x10
10x10
254x254
254x254
1/2 (1050)
1/2 (1050)
20x20x1
20x24x1
508x508x25
508x610x25
Table 2 – Minimum Airflow for Safe Electric Heater Operation (CFM)
30
1000
Specifications are subject to change without notice.
supplemental heat, connect white and violet wires shown in Fig. 10
to second stage heat field wire.
Some electric heaters have four control wires (plus common wire).
Consult unit wiring diagram and electric heater wiring diagram for
additional details.

TRANSFORMER PROTECTION

The transformer is of the energy- -limiting type, however a direct
short will likely blow a secondary fuse. If an overload or short is
present, correct overload condition and check for blower fuse on
Indoor Fan Board. Replace fuse as required with correct size and
rating.
36
42
3
3 ---1/2
420
466
191
212
Scroll
1
11.0
14.6
5.0
6.6
TXV, Indoor TXV
.
.038 (1)
042 (2)
.042 (2)
.97 (1)
1.07 (2)
1.07 (2)
2...21
2...21
13.6
19.4
3000
3000
26
26
660.4
660.4
1/5 (810)
1/5 (810)
3...17
3...17
4.7
4.7
900
900
1050
1050
1200
1400
11x10
11x10
279.4x254
279.4x254
3/4 (1000)
3/4 (1075)
650 +/ --- 15
420 +/ --- 25
20 +/ --- 5
45 +/ --- 5
24x30x1
610x762x25
36
42
1200
1400
48
60
4
5
462
511
210
232
12.0
14.8
5.4
6.7
.042 (2)
.052 (2)
1.07 (2)
1.32 (2)
2...21
2...21
17.5
23.3
3300
3600
26
26
660.4
660.4
1/5 (810)
1/5 (810)
3...17
4...17
5.7
5.7
1200
1200
1400
1400
1600
1750
11x10
11x10
279.4x254
279.4x254
1.0 (1075)
1.0 (1075)
24x36x1
610x914x25
48
60
1600
1750
51801210406

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents